Schneider Electric TeSys GV2 Motor Circuit Breaker, 3P, 1A, Magnetic, Toggle Control, Screw Clamp Terminals
Schneider Electric TeSys GV2 Motor Circuit Breaker, 3P, 1A, Magnetic, Toggle Control, Screw Clamp Terminals is available to buy in increments of 1
Quick Overview
Range of product: TeSys Deca
Product type: Motor circuit breaker
Device application: Motor protection
Poles: 3P
TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for 3-phase motor applications 0.25-0.37kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD05 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications:
| |
Main | |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| device short name | GV2LE |
| Device application | Motor protection |
| Trip unit technology | Magnetic |
| Complementary | |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 |
| AC-3 conforming to IEC 60947-4-1 | |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Fixing mode | 35 mm symmetrical DIN rail: clipped |
| Panel: screwed (with adaptor plate) | |
| Motor power kW | 0.25 kW at 400/415 V AC 50/60 Hz |
| 0.37 kW at 400/415 V AC 50/60 Hz | |
| 0.37 kW at 500 V AC 50/60 Hz | |
| 0.55 kW at 690 V AC 50/60 Hz | |
| 0.75 kW at 690 V AC 50/60 Hz | |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
| control type | Toggle |
| [In] rated current | 0.041666667 |
| Weight | 0.330000 |
|---|---|
| Brand | Schneider Electric |
| Model | GV2LE05 |
| Color | White |
| Device Application | Motor protection |
| Width [cm] | 4.5 |
| Height [cm] | 8.9 |
| Range | GV |
| Family | PPCTR |
| Type | Motor Circuit Breaker |
| Poles | 3P |
| [In] Rated Current | 1 A |
| Voltage ~ Frequency | 50-60 Hz |
| IP Degree of Protection | IP20 |
| IK Degree of Protection | IK04 |
Write Your Own Review