Schneider Electric TeSys GV2 Motor Circuit Breaker, 3P, 0.63A, Magnetic, Toggle Control, Screw Clamp Terminals

In stock
SKU
GV2LE04
Schneider Electric
Special Price EGP 2,869 Regular Price EGP 5,312
Estimated Time of Delivery is 72 Hours.

The Installment Amount Is Approximate. The Actual Amount Will Be Shown During The Payment Process.

  • Bank Installment
  • Direct Installment
Schneider Electric TeSys GV2 Motor Circuit Breaker, 3P, 0.63A, Magnetic, Toggle Control, Screw Clamp Terminals is available to buy in increments of 1
Quick Overview

Range of product: TeSys Deca
Product type: Motor circuit breaker
Device application: Motor protection
Poles: 3P

The GV2LE04 TeSys GV2 Motor Circuit Breaker is an essential component for motor protection and control in industrial settings. With three poles and a current rating of 0.63A, this circuit breaker offers versatile protection for motors of different sizes. It features a magnetic trip unit, a convenient toggle control for easy operation, and secure screw clamp terminals for reliable connections.

Specifications:

Main
RangeTeSys Deca
Product nameTeSys GV2
Product or component typeMotor circuit breaker
device short nameGV2LE
Device applicationMotor protection
Trip unit technologyMagnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-2
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Motor power kW0.12 kW at 400/415 V AC 50/60 Hz
0.18 kW at 400/415 V AC 50/60 Hz
0.37 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
control typeToggle
[In] rated current0.63 A
Magnetic tripping current08:00 ص
[Ith] conventional free air thermal current0.63 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole1.8 W
Mechanical durability100000 cycles
Electrical durability100000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque1.7 N.m - on screw clamp terminal
Width45 mm
height89 mm
Depth78.5 mm
Net weight0.33 kg
ColourDark grey
Environment
standardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
RINA
DNV-GL
UKCA
IECEE CB Scheme
IK degree of protectionIK04
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5...150 Hz
Operating altitude2000 m
More Information
Weight0.330000
BrandSchneider Electric
ModelGV2LE04
ColorWhite
Device ApplicationMotor protection
Width [cm]4.5
Height [cm]8.9
RangeGV
FamilyPPCTR
TypeMotor Circuit Breaker
Poles3P
[In] Rated Current0.63 A
Voltage ~  Frequency50-60 Hz
IP Degree of ProtectionIP20
IK Degree of ProtectionIK04
0