Schneider Electric Power Factor Controller, VarPlus Logic, VPL 6

In stock
SKU
VPL06N
Schneider Electric
Special Price EGP 20,648 Regular Price EGP 27,531

The Installment Amount Is Approximate. The Actual Amount Will Be Shown During The Payment Process.

  • Bank Installment
  • Direct Installment
Schneider Electric Power Factor Controller, VarPlus Logic, VPL 6 is available to buy in increments of 1
Quick Overview

Range: PowerLogic
Product type: Power factor controller
Display type: Backlit LCD
Display size: 56 x 25 mm

VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor. It is a simple and intelligent relay which measures,monitor and Controls the reactive energy. It comes with Easy Commisioning ,Step Size detection and monitoring along with the variour alarms. VPL06 can be used for 6 steps in a PFC equippment.

Specifications:

Main 
RangePowerLogic
product namePowerLogic PFC Controller
Product or component typePower factor controller
Device short nameVPL6
Complementary 
Number of step output contacts٦
[Us] rated supply voltage90...550 V AC
 <= 999 kV AC with external VT
Measurement current0…5 A
Measurement voltage90…550 V AC 50/60 Hz
Operating modeManual or automatic
Number of quadrant operation for generator application٤
Device connectionCommunication protocol: Modbus interface: RS485
Input functionSwitch: 1 x dry contact
Colour codeFront: dark grey RAL 7016
Display typeBacklit LCD
Display size56 x 25 mm
Function availableAutomatic detection
 Advanced programming (expert)
 Manual programming
 Any step sequence
 Automatic initialisation
Metering typePower factor and displacement PF (signed, four quadrant)
 Total current harmonic distortion THD (I)
 Power factor average over lifetime
 Temperature maximum
 Phase current I1, I2, I3 RMS on load
 Active power P, P1, P2, P3 on load
 Reactive power Q, Q1, Q2, Q3 on load
 Apparent power S, S1, S2, S3 on load
 Voltage U21, U32, U13, V1, V2, V3 on load
Type of measurementAmbient temperature inside the cubicle
 Tan φ
 Individual voltage harmonic
 Cos φ
 Operating time
 Power factor
 Capacitor current overload Irms/I1
Information displayedNumber of switching cycles per step
 Remaining step capacity in %
 Individual step size in kVAr
Type of alarmsStep power loss (< 75 %) / Action: message and alarm contact + step blocked
 Step faulty / Action: message and alarm contact + step blocked
 High current (> 6 A CT) / Action: message and alarm contact
 Hunting (unstable regulation) / Action: message and alarm contact + step blocked
 Low current (< 15 mA CT) / Action: message and alarm contact
 Overcompensation / Action: message and alarm contact
 Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
 Overtemperature (50 °C) / Action: message and alarm contact + step switched off
 Overtemperature (30 °C) / Action: fan switch
 Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
 Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Data recording5 alarms
Operational Hours alarm100000 h without maintenance
Operational counter alarm65000 cycles without maintenance
Input typeInsensitive to phase rotation polarity
 Insensitive to CT polarity
 Phase to neutral
 Current input CT...X/5 A and X/1 A
 Phase to phase
Output typeControl relay: 0.2 A 110 V DC
 Control relay: 1 A 48 V DC
 Control relay: 2 A 400 V AC 50/60 Hz
 Control relay: 1 A 24 V DC
 Control relay: 5 A 250 V AC 50/60 Hz
 Control relay: 5 A 120 V AC 50/60 Hz
 Fan: 5 A 250 V AC 50/60 Hz
 Fan: 1 A 48 V DC
 Alarm relay: 5 A 250 V AC 50/60 Hz
 Alarm relay: 1 A 48 V DC
Maximum at the common terminal10:00 AM
Settings operating modeManual
 Automatic
Type of settingChoice of stepping programs: auto
 Choice of stepping programs: LIFO
 Choice of stepping programs: linear
 Delay between 2 successive switch on the same step: 5...1200 s
 Step configuration programming: auto
 Step configuration programming: off
 Step configuration programming: fixed
 Target cos phi: 0.7 inductive...0.7 capacitive
 Target cos phi: dual cos φ
Measurement accuracyVoltage +/- 1 %
 Current +/- 1 %
 Frequency +/- 1 %
 Energy (P,Q,S) +/- 2 %
 Cos φ +/- 2 %
 Total voltage harmonic distortion THD (U) +/- 2 %
 Individual voltage harmonic +/- 3 %
 Temperature +/- 3 °C
Time delay range1...6500 s (on reconnection)
 1...6500 s (on response)
Provided equipmentUser manual
Mounting modeFlush-mounted
Mounting supportPanel - thickness: 1…3 mm
Mounting locationIn cabinet
Cut-out dimensions138 x 138 mm
Height144 mm
Width144 mm
Depth58 mm
Net weight0.6 kg
Compatibility codeVPL 6
Environment 
StandardsIEC 61000-6-2
 EN 61010-1
 IEC 61000-6-4
 IEC 61326-1
 UL 61010-1
Product certificationsEAC
 NRTL
 cNRTL
 CE
IP degree of protectionFront face: IP41
 Rear face: IP20
Operating altitude<= 2000 m
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…85 °C
More Information
Weight3.000000
BrandSchneider Electric
ModelVPL06N
RangePFC
FamilyDPLVP
0
Rating:
0% of 100
Write Your Own Review
You're reviewing:Schneider Electric Power Factor Controller, VarPlus Logic, VPL 6
Your Rating
WhatsApp Chat WhatsApp Chat