High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions.
Specifications:
Main Input Voltage |
230 V |
Product or component type |
Uninterruptible power supply (UPS) |
Other Input Voltage |
220 V |
240 V |
|
Main Output Voltage |
230 V |
Other Output Voltage |
220 V |
240 V |
|
Rated power in W |
1600 W |
Rated power in VA |
2000 VA |
Input Connection Type |
IEC 60320 C14 |
output connection type |
4 IEC 60320 C13 |
Number of rack unit |
2U |
Cable length |
1.50 m |
Number of cables |
1 |
Provided equipment |
1 IEC 60320 C13 to Schuko power cable |
1 IEC 60320 C13 to C14 power cable |
|
1 USB cable |
|
1 RS-232 configuration cable |
|
1 rack mounting brackets |
|
1 user manual |
|
Range of product |
Easy UPS On-Line |
Batteries & Runtime |
|
Battery type |
Lead-acid battery |
Battery voltage |
48 V |
Number of battery filled slots |
0 |
Number of battery free slots |
0 |
Battery recharge time |
4 h |
Battery life |
3…5 year(s) |
Battery charger power |
70 W rated |
General |
|
Max runtime |
4 min |
Number of power module filled slots |
0 |
Number of power module free slots |
0 |
Redundant |
No |
Physical |
|
Colour |
Black (RAL 7010) |
Height |
8.6 cm |
Width |
43.7 cm |
Depth |
46.2 cm |
Net weight |
18.2 kg |
mounting location |
Front |
Mounting preference |
Lower |
mounting mode |
Rack-mounted with kit |
USB compatible |
Yes |
Mounting position |
Horizontal |
Input |
|
Input voltage limits |
110...285 V half load |
160...280 V full load |
|
Network frequency |
40...70 Hz auto sensing |
Output |
|
Maximum configurable power in VA |
2000 VA |
Maximum configurable power in W |
1600 W |
Output frequency |
50/60 Hz +/- 3 Hz sync to mains |
Harmonic distortion |
3 % |
UPS type |
Double conversion online |
Wave type |
Sine wave |
Efficiency |
88 % (full load) |
Additional information |
Configurable for 220 : 230 or 240 nominal output voltage |
Bypass type |
Internal bypass (automatic and manual) |
Crest factor |
3: |
Conformance |
|
product certifications |
CE |
EAC |
|
TISI |
|
Standards |
EN/IEC 62040-1:2019/A11:2021 |
EN/IEC 62040-2:2006/AC:2006 |
|
EN/IEC 62040-2:2018 |
|
Environmental |
|
Ambient air temperature for operation |
0…40 °C |
Relative humidity |
0…95 % non-condensing |
Operating altitude |
0...3000 m |
Ambient air temperature for storage |
-20…50 °C |
Storage Relative Humidity |
0…95 % non-condensing |
Storage altitude |
0…15000 m |
acoustic level |
50 dBA |
Heat dissipation |
745 Btu/h |
IP degree of protection |
IP20 |
Communications & Management |
|
Alarm |
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Free slots |
1 |
Control panel |
Multifunction LCD status and control console |
Surge Protection and Filtering |
|
Surge energy rate |
600 J |