Schneider Electric Variable Speed Drive ATV930, 55 kW, 400-480V, With Braking Unit, IP21
Range of product: Altivar Machine ATV320
Product type: Variable speed drive
Product specific application: Complex machines
Variant: Standard version
The ATV930D55N4 Variable Speed Drive ATV930 is a powerful and efficient solution designed for precise motor speed control in demanding industrial applications. With a power rating of 55 kW, this drive is suitable for systems operating at 400-480V. It features a built-in braking unit that allows for efficient deceleration and braking control. The drive is equipped with an IP21 protection rating, ensuring its durability and safety in industrial environments.
Key Features:
High Power: With a power rating of 55 kW, this drive is suitable for high-capacity industrial applications.
Braking Unit: Equipped with a built-in braking unit for effective deceleration and braking processes.
Voltage Compatibility: Designed for systems operating at 400-480V, providing versatility for various industrial setups.
Durable Build: The drive is protected by an IP21 rating, making it robust and safe for use in industrial environments.
Technical Specifications:
Product Type: Variable Speed Drive
Power Rating: 55 kW
Voltage Rating: 400-480V
Braking Unit: Included
Protection Rating: IP21
Specifications | |
Main | |
Range of product | Altivar Process ATV900 |
Device application | Industrial application |
Product or component type | Variable speed drive |
Product destination | Asynchronous motors |
Synchronous motors | |
Product specific application | Process for industrial |
Variant | With braking chopper |
Standard version | |
Network number of phases | 3 phases |
Mounting mode | Wall mount |
Communication port protocol | EtherNet/IP |
Modbus TCP | |
Modbus serial | |
[Us] rated supply voltage | 380...480 V - 15...10 % |
Motor power kW | 55.0 kW for normal duty |
45.0 kW for heavy duty | |
Continuous output current | 106 A at 2.5 kHz for normal duty |
88 A at 2.5 kHz for heavy duty | |
EMC filter | Integrated |
With EMC plate option | |
IP degree of protection | IP21 |
Degree of protection | UL type 1 |
option module | Slot A: communication module for Profibus DP V1 |
Slot A: communication module for PROFINET | |
Slot A: communication module for DeviceNet | |
Slot A: communication module for EtherCAT | |
Slot A: communication module for CANopen daisy chain RJ45 | |
Slot A: communication module for CANopen SUB-D 9 | |
Slot A: communication module for CANopen screw terminals | |
Slot A/slot B/slot C: digital and analog I/O extension module | |
Slot A/slot B/slot C: output relay extension module | |
Slot B: 5/12 V digital encoder interface module | |
Slot B: analog encoder interface module | |
Slot B: resolver encoder interface module | |
communication module for Ethernet Powerlink | |
Discrete input logic | 16 preset speeds |
Asynchronous motor control profile | Constant torque standard |
Optimized torque mode | |
Variable torque standard | |
Synchronous motor control profile | Permanent magnet motor |
Synchronous reluctance motor | |
Maximum output frequency | 599 Hz |
Switching frequency | 1...8 kHz adjustable |
2.5...8 kHz with derating factor | |
Nominal switching frequency | 2.5 kHz |
Line current | 97.2 A at 380 V (normal duty) |
81.4 A at 380 V (heavy duty) | |
84.2 A at 480 V (normal duty) | |
71.8 A at 480 V (heavy duty) | |
Apparent power | 70 kVA at 480 V (normal duty) |
59.7 kVA at 480 V (heavy duty) | |
Maximum transient current | 127.2 A during 60 s (normal duty) |
132 A during 60 s (heavy duty) | |
Network frequency | 50...60 Hz |
Prospective line Isc | 50 kA |
Complementary | |
Discrete input number | 10 |
Discrete input type | DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm |
DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) | |
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm | |
Discrete output number | 2 |
Discrete output type | Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA |
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA | |
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA | |
analogue input number | 3 |
Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits |
AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits | |
analogue output number | 2 |
Analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits | |
Relay output number | 3 |
Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles |
Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles | |
Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles | |
Maximum switching current | Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC |
Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC | |
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC | |
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC | |
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC | |
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC | |
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC | |
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC | |
Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
Physical interface | Ethernet |
2-wire RS 485 | |
Connector type | 2 RJ45 |
1 RJ45 | |
Method of access | Slave Modbus TCP |
Transmission rate | 10, 100 Mbits |
4.8 kbps | |
9600 bit/s | |
19200 bit/s | |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance |
4 quadrant operation possible | TRUE |
Acceleration and deceleration ramps | Linear adjustable separately from 0.01...9999 s |
Motor slip compensation | Automatic whatever the load |
Not available in permanent magnet motor law | |
Can be suppressed | |
Adjustable | |
Braking to standstill | By DC injection |
Brake chopper integrated | TRUE |
Maximum input current | 97.2 A |
Maximum output voltage | 480.0 V |
Relative symmetric network frequency tolerance | 5% |
Base load current at high overload | 88.0 A |
Base load current at low overload | 106.0 A |
Power dissipation in W | Natural convection: 131 W at 380 V, switching frequency 2.5 kHz |
Forced convection: 917 W at 380 V, switching frequency 2.5 kHz | |
With safety function Safely Limited Speed (SLS) | TRUE |
With safety function Safe brake management (SBC/SBT) | TRUE |
With safety function Safe Operating Stop (SOS) | FALSE |
With safety function Safe Position (SP) | FALSE |
With safety function Safe programmable logic | FALSE |
With safety function Safe Speed Monitor (SSM) | FALSE |
With safety function Safe Stop 1 (SS1) | TRUE |
With sft fct Safe Stop 2 (SS2) | FALSE |
With safety function Safe torque off (STO) | TRUE |
With safety function Safely Limited Position (SLP) | FALSE |
With safety function Safe Direction (SDI) | FALSE |
Protection type | Thermal protection: motor |
Safe torque off: motor | |
Motor phase break: motor | |
Thermal protection: drive | |
Safe torque off: drive | |
Overheating: drive | |
Overcurrent between output phases and earth: drive | |
Overload of output voltage: drive | |
Short-circuit protection: drive | |
Motor phase break: drive | |
Overvoltages on the DC bus: drive | |
Line supply overvoltage: drive | |
Line supply undervoltage: drive | |
Line supply phase loss: drive | |
Overspeed: drive | |
Break on the control circuit: drive | |
Quantity per set | 1 |
Width | 290 mm |
height | 922 mm |
Depth | 325.5 mm |
Net weight | 57.5 kg |
Electrical connection | Control: screw terminal 0.5...1.5 mm²/AWG 20...AWG 16 |
Line side: screw terminal 70...120 mm²/AWG 1/0...250 kcmil | |
Motor: screw terminal 70...120 mm²/AWG 1/0...250 kcmil | |
DC bus: screw terminal 70...120 mm²/AWG 1/0...250 kcmil | |
Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP |
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial | |
Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
Type of polarization | No impedance for Modbus serial |
Number of addresses | 1…247 for Modbus serial |
Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection |
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection | |
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection | |
Local signalling | Local diagnostic: 3 LED (mono/dual colour) |
Embedded communication status: 5 LED (dual colour) | |
Communication module status: 2 LED (dual colour) | |
Presence of voltage: 1 LED (red) | |
Input compatibility | DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68 | |
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 | |
Discrete input logic | Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1) |
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1) | |
Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1) | |
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) | |
Sampling duration | 2 ms +/- 0.5 ms (DI1...DI8) - discrete input |
5 ms +/- 1 ms (DI7, DI8) - pulse input | |
1 ms +/- 1 ms (AI1, AI2, AI3) - analog input | |
5 ms +/- 1 ms (AQ1, AQ2) - analog output | |
Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input |
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output | |
Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input |
AQ1, AQ2: +/- 0.2 % for analog output | |
Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Isolation | Between power and control terminals |
Environment | |
Operating altitude | <= 1000 m without derating |
1000...4800 m with current derating 1 % per 100 m | |
Operating position | Vertical +/- 10 degree |
product certifications | CSA |
UL | |
TÜV | |
Marking | CE |
standards | UL 508C |
EN/IEC 61800-3 | |
EN/IEC 61800-5-1 | |
IEC 61000-3-12 | |
IEC 60721-3 | |
IEC 61508 | |
IEC 13849-1 | |
Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
Assembly style | Enclosed |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 |
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 | |
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 | |
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 | |
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 | |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 |
Class 3S3 according to IEC 60721-3-3 | |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
Volume of cooling air | 295 m3/h |
Overvoltage category | III |
Regulation loop | Adjustable PID regulator |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Noise level | 68.3 dB conforming to 86/188/EEC |
Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 |
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 | |
Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Environmental characteristic | Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 |
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 | |
Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
Ambient air temperature for operation | -15…50 °C (without derating) |
50…60 °C (with derating factor) | |
Noise level | 68.3 dB |
Pollution degree | 2 |
Ambient air transport temperature | -40…70 °C |
Ambient air temperature for storage | -40…70 °C |
Weight | 57.500000 |
---|---|
Brand | Schneider Electric |
Model | ATV930D55N4 |
Width [cm] | 29 |
Height [cm] | 92.2 |
Range | ATV930 |
Family | IDVSD |