Pendant control station XAC-A - 5 pushbuttons 1 Emergency stop, Schneider Electric
Range of product:Harmony XAC
Product type: Pendant control station
Control station type:Double insulated
Electrical circuit type: Control circuit
Introducing the Schneider Electric XACA6913 Control Station – a versatile and robust solution for your industrial control needs. This control station features two buttons, one for start and the other for stop functions. Equipped with 1 normally open (NO) and 1 normally closed (NC) contact, it offers flexible control options. With an IP66 rating, it provides protection against dust and water ingress, making it suitable for various industrial applications.
Key Features:
Two-Button Control: The XACA6913 control station is designed with a two-button layout for easy and efficient start/stop control, enhancing safety and productivity.
1NO/1NC Contacts: With both normally open and normally closed contacts, this station provides versatility for control applications.
IP66 Rated: This control station is rated IP66, ensuring it can withstand challenging industrial environments with dust and water resistance.
Durable Build: Constructed with high-quality materials, it is built to withstand tough operating conditions.
Technical Specifications:
Buttons: Two (Start and Stop)
Contacts: 1NO/1NC
IP Rating: IP66
Specifications
| Main | |
| Range of product | Harmony XAC |
| Product or component type | Pendant control station |
| Device short name | XACA |
| Complementary | |
| Control station type | Double insulated |
| Enclosure material | Polypropylene |
| Electrical circuit type | Control circuit |
| Enclosure type | Complete ready for use |
| Control station application | Control of 2-speed hoist motor |
| Control station composition | 7 push-buttons + 1 emergency stop |
| Control button type | Emergency stop push-button Ø 40 mm 1 NC trigger action blank |
| First push-button 1 NC + 1 NO + 1 NO raise, slow-fast | |
| Second push-button 1 NC + 1 NO + 1 NO lower, slow-fast | |
| Third push-button 1 NC + 1 NO + 1 NO left, slow-fast | |
| Fourth push-button 1 NC + 1 NO + 1 NO right, slow-fast | |
| Fifth push-button 1 NC + 1 NO + 1 NO forward, slow-fast | |
| Product compatibility | ZB2BE102 for emergency stop |
| ZB2BE102 + ZB2BE101 for each direction | |
| XENG1191 | |
| Mechanical interlocking | With mechanical interlocking between pairs |
| Control station colour | Yellow |
| Connections - terminals | Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end |
| Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end | |
| standards | IEC 60947-5-1 |
| IEC 60204-32 | |
| CSA C22.2 No 14 | |
| UL 508 | |
| IEC 60947-5-5 | |
| EN/ISO 13850: 2006 | |
| product certifications | CCC |
| GOST | |
| Protective treatment | TH |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 100 gn conforming to IEC 60068-2-27 |
| Overvoltage category | Class II conforming to IEC 61140 |
| IP degree of protection | IP65 conforming to IEC 60529 |
| IK degree of protection | IK08 conforming to IEC 62262 |
| Mechanical durability | 1000000 cycles |
| Cable entry | Rubber sleeve with stepped entry 8…26 mm |
| Contact code designation | A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A |
| A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A | |
| Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A | |
| Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A | |
| [Ithe] conventional enclosed thermal current | 10:00 ص |
| [Ui] rated insulation voltage | Emergency stop contact: 400 V (pollution degree 3) conforming to IEC 60947-1 |
| 600 V (pollution degree 3) | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| contact operation | Slow-break |
| Maximum resistance across terminals | 25 MOhm |
| Operating force | 13 N push-button |
| 14 N emergency stop | |
| Short-circuit protection | 10 A fuse protection by cartridge fuse type gG |
| Rated operational power in W | 40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
| 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C | |
| 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C | |
| Terminals description ISO n°1 | (13-14)NO |
| (11-12)NC | |
| Terminals description ISO n°2 | (31-32)NC |
| (11-12)NC | |
| (21-22)NC | |
| Terminal identifier | (11-12)NC |
| (13-14)NO | |
| Net weight | 0.97 kg |
| Weight | 0.970000 |
|---|---|
| Brand | Schneider Electric |
| Model | XACA6913 |
| Color | Yellow |
| Range | PendantStations |
| Family | IDSIG |






The information below is required for social login