Compact NSX100F Circuit Breaker, 36kA at 415VAC, Micrologic 2.2 Trip Unit, 100A, 4 Poles, 4D
Product or component type: Circuit breaker
Device application: Distribution
Number of poles: 4P
[in] Rated Current: 100 A at 40 °C
Introducing the Schneider Electric Compact NSX100F Circuit Breaker, a reliable and high-performance solution for circuit protection. Engineered to ensure the safety and efficiency of your electrical systems, this circuit breaker offers robust protection capabilities, making it suitable for a variety of applications.
Key Features:
High Breaking Capacity: With an impressive 36kA breaking capacity at 415VAC, this circuit breaker can handle high fault currents, enhancing the safety of your electrical circuits.
4 Poles: The 4-pole configuration adds versatility to your electrical system, making it suitable for various applications and installations.
Micrologic 2.2 Trip Unit: Equipped with the advanced Micrologic 2.2 trip unit, this circuit breaker offers intelligent protection with enhanced features for precise fault detection and response.
100A Rating: The 100A rating allows this circuit breaker to handle moderate to heavy electrical loads while providing reliable protection.
4D Compatibility: The 4D designation signifies its compatibility with a range of tripping units, ensuring flexible protection options.
Technical Specifications:
Breaking Capacity: 36kA at 415VAC
Poles: 4
Trip Unit Type: Micrologic 2.2
Current Rating: 100A
Tripping Units Compatibility: 4D
Specifications | |
Main | |
Range | ComPacT new generation |
Product name | ComPacT NSX new generation |
device short name | NSX100F |
Product or component type | Circuit breaker |
Device application | Distribution |
Poles description | 4P |
Protected poles description | 4D |
3D + N/2 | |
3D | |
Neutral position | Left |
[In] rated current | 100 A at 40 °C |
[Ue] rated operational voltage | 690 V AC 50/60 Hz |
Network type | AC |
Network frequency | 50/60 Hz |
Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
utilisation category | Category A |
[Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 | |
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | F 36 kA 415 V AC |
Trip unit name | MicroLogic 2.2 |
Trip unit technology | Electronic |
Trip unit protection functions | LSoI |
control type | Toggle |
Circuit breaker mounting mode | Fixed |
Complementary | |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
[Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 | |
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Mechanical durability | 50000 cycles |
Electrical durability | 50000 cycles at 440 V In/2 |
30000 cycles at 440 V In | |
20000 cycles at 690 V In/2 | |
10000 cycles at 690 V In | |
Power dissipation per pole | 4.7 W |
mounting support | Backplate |
Mounting position | Horizontal and vertical |
Flat on the back | |
Upside connection | Front |
downside connection | Front |
Connection pitch | 35 mm |
Protection type | L : for overload protection (long time) |
So : for short time short-circuit protection with fixed delay | |
I : for instantaneous short-circuit protection | |
Trip unit rating | 100 A at 40 °C |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
[Ir] long-time protection pick-up adjustment range | 40...100 A |
Long-time protection delay adjustment type tr | Fixed |
[tr] long-time protection delay adjustment range | 400 s at 1.5 x Ir |
16 s at 6 x Ir | |
11 s at 7.2 x Ir | |
Neutral protection settings | 0.5 x Ir (3D + N/2) |
1 x Ir (4D) | |
No protection (3D) | |
thermal memory | 20 minutes before and after tripping |
Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
[Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
Short-time protection delay adjustment type tsd | Fixed |
Instantaneous protection pick-up adjustment type Ii | Fixed |
[Ii] instantaneous protection pick-up adjustment range | 1500 A |
earth-leakage protection | Without |
Zone selective interlocking ZSI | Without |
Number of slots for electrical auxiliaries | 5 slot(s) |
Local signalling | Flashing LED (green) for ready to operate |
LED 105 % Ir (red) for overload | |
LED 90 % Ir (orange) for overload | |
Width (W) | 140 mm |
Height (H) | 161 mm |
Depth (D) | 86 mm |
Weight | 2.400000 |
---|---|
Brand | Schneider Electric |
Model | C10F42D100 |
Device Application | Distribution |
Depth [cm] | 8.6 |
Width [cm] | 14 |
Height [cm] | 16.1 |
Range | NSX |
Family | PPCCB |
Type | Circuit Breaker |
Poles | 4P |
[In] Rated Current | 100 A at 40 °C |