Compact NSX100F Circuit Breaker, 36kA at 415VAC, Micrologic 2.2 Trip Unit, 100A, 4 Poles, 4D

Out of stock
SKU
C10F42D100
Special Price EGP 24,709 Regular Price EGP 37,438
494180 Reward Points will be used to purchase this product
Quick Overview

Product or component type: Circuit breaker
Device application: Distribution
Number of poles: 4P
[in] Rated Current: 100 A at 40 °C

Introducing the Schneider Electric Compact NSX100F Circuit Breaker, a reliable and high-performance solution for circuit protection. Engineered to ensure the safety and efficiency of your electrical systems, this circuit breaker offers robust protection capabilities, making it suitable for a variety of applications.

 

Key Features:

High Breaking Capacity: With an impressive 36kA breaking capacity at 415VAC, this circuit breaker can handle high fault currents, enhancing the safety of your electrical circuits.

4 Poles: The 4-pole configuration adds versatility to your electrical system, making it suitable for various applications and installations.

Micrologic 2.2 Trip Unit: Equipped with the advanced Micrologic 2.2 trip unit, this circuit breaker offers intelligent protection with enhanced features for precise fault detection and response.

100A Rating: The 100A rating allows this circuit breaker to handle moderate to heavy electrical loads while providing reliable protection.

4D Compatibility: The 4D designation signifies its compatibility with a range of tripping units, ensuring flexible protection options.

Technical Specifications:

Breaking Capacity: 36kA at 415VAC

Poles: 4

Trip Unit Type: Micrologic 2.2

Current Rating: 100A

Tripping Units Compatibility: 4D

Specifications 

Main

 
RangeComPacT new generation
Product nameComPacT NSX new generation
device short nameNSX100F
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description4D
 3D + N/2
 3D
Neutral positionLeft
[In] rated current100 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelF 36 kA 415 V AC
Trip unit nameMicroLogic 2.2
Trip unit technologyElectronic
Trip unit protection functionsLSoI
control typeToggle
Circuit breaker mounting modeFixed
Complementary 
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability50000 cycles
Electrical durability50000 cycles at 440 V In/2
 30000 cycles at 440 V In
 20000 cycles at 690 V In/2
 10000 cycles at 690 V In
Power dissipation per pole4.7 W
mounting supportBackplate
Mounting positionHorizontal and vertical
 Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (long time)
 So : for short time short-circuit protection with fixed delay
 I : for instantaneous short-circuit protection
Trip unit rating100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range40...100 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
 16 s at 6 x Ir
 11 s at 7.2 x Ir
Neutral protection settings0.5 x Ir (3D + N/2)
 1 x Ir (4D)
 No protection (3D)
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5...10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1500 A
earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries5 slot(s)
Local signallingFlashing LED (green) for ready to operate
 LED 105 % Ir (red) for overload
 LED 90 % Ir (orange) for overload
Width (W)140 mm
Height (H)161 mm
Depth (D)86 mm

 

 

More Information
Weight2.400000
BrandSchneider Electric
ModelC10F42D100
Device ApplicationDistribution
Depth [cm]8.6
Width [cm]14
Height [cm]16.1
RangeNSX
FamilyPPCCB
TypeCircuit Breaker
Poles4P
[In] Rated Current100 A at 40 °C
0
Rating:
0% of 100
Write Your Own Review
You're reviewing:Compact NSX100F Circuit Breaker, 36kA at 415VAC, Micrologic 2.2 Trip Unit, 100A, 4 Poles, 4D
Your Rating
WhatsApp Chat WhatsApp Chat