Compact NSX100F Circuit Breaker, 36kA at 415VAC, Micrologic 2.2 Trip Unit, 100A, 4 Poles, 4D
Product or component type: Circuit breaker
Device application: Distribution
Number of poles: 4P
[in] Rated Current: 100 A at 40 °C
Introducing the Schneider Electric Compact NSX100F Circuit Breaker, a reliable and high-performance solution for circuit protection. Engineered to ensure the safety and efficiency of your electrical systems, this circuit breaker offers robust protection capabilities, making it suitable for a variety of applications.
Key Features:
High Breaking Capacity: With an impressive 36kA breaking capacity at 415VAC, this circuit breaker can handle high fault currents, enhancing the safety of your electrical circuits.
4 Poles: The 4-pole configuration adds versatility to your electrical system, making it suitable for various applications and installations.
Micrologic 2.2 Trip Unit: Equipped with the advanced Micrologic 2.2 trip unit, this circuit breaker offers intelligent protection with enhanced features for precise fault detection and response.
100A Rating: The 100A rating allows this circuit breaker to handle moderate to heavy electrical loads while providing reliable protection.
4D Compatibility: The 4D designation signifies its compatibility with a range of tripping units, ensuring flexible protection options.
Technical Specifications:
Breaking Capacity: 36kA at 415VAC
Poles: 4
Trip Unit Type: Micrologic 2.2
Current Rating: 100A
Tripping Units Compatibility: 4D
| Specifications | |
Main | |
| Range | ComPacT new generation |
| Product name | ComPacT NSX new generation |
| device short name | NSX100F |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 4D |
| 3D + N/2 | |
| 3D | |
| Neutral position | Left |
| [In] rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 | |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | MicroLogic 2.2 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSoI |
| control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| Complementary | |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 | |
| 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 | |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 |
| 30000 cycles at 440 V In | |
| 20000 cycles at 690 V In/2 | |
| 10000 cycles at 690 V In | |
| Power dissipation per pole | 4.7 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical |
| Flat on the back | |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (long time) |
| So : for short time short-circuit protection with fixed delay | |
| I : for instantaneous short-circuit protection | |
| Trip unit rating | 100 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 40...100 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 400 s at 1.5 x Ir |
| 16 s at 6 x Ir | |
| 11 s at 7.2 x Ir | |
| Neutral protection settings | 0.5 x Ir (3D + N/2) |
| 1 x Ir (4D) | |
| No protection (3D) | |
| thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1500 A |
| earth-leakage protection | Without |
| Zone selective interlocking ZSI | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Local signalling | Flashing LED (green) for ready to operate |
| LED 105 % Ir (red) for overload | |
| LED 90 % Ir (orange) for overload | |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Weight | 2.400000 |
|---|---|
| Brand | Schneider Electric |
| Model | C10F42D100 |
| Device Application | Distribution |
| Depth [cm] | 8.6 |
| Width [cm] | 14 |
| Height [cm] | 16.1 |
| Range | NSX |
| Family | PPCCB |
| Type | Circuit Breaker |
| Poles | 4P |
| [In] Rated Current | 100 A at 40 °C |