Compact NSX100F Circuit Breaker, 36kA at 415VAC, Micrologic 2.2 Trip Unit, 100A, 4 Poles, 4D

Out of stock
SKU
C10F42D100
Schneider Electric
Special Price EGP 24,709 Regular Price EGP 37,438
Estimated Time of Delivery is 72 Hours.

The Installment Amount Is Approximate. The Actual Amount Will Be Shown During The Payment Process.

  • Bank Installment
  • Direct Installment
Quick Overview

Product or component type: Circuit breaker
Device application: Distribution
Number of poles: 4P
[in] Rated Current: 100 A at 40 °C

Introducing the Schneider Electric Compact NSX100F Circuit Breaker, a reliable and high-performance solution for circuit protection. Engineered to ensure the safety and efficiency of your electrical systems, this circuit breaker offers robust protection capabilities, making it suitable for a variety of applications.

 

Key Features:

High Breaking Capacity: With an impressive 36kA breaking capacity at 415VAC, this circuit breaker can handle high fault currents, enhancing the safety of your electrical circuits.

4 Poles: The 4-pole configuration adds versatility to your electrical system, making it suitable for various applications and installations.

Micrologic 2.2 Trip Unit: Equipped with the advanced Micrologic 2.2 trip unit, this circuit breaker offers intelligent protection with enhanced features for precise fault detection and response.

100A Rating: The 100A rating allows this circuit breaker to handle moderate to heavy electrical loads while providing reliable protection.

4D Compatibility: The 4D designation signifies its compatibility with a range of tripping units, ensuring flexible protection options.

Technical Specifications:

Breaking Capacity: 36kA at 415VAC

Poles: 4

Trip Unit Type: Micrologic 2.2

Current Rating: 100A

Tripping Units Compatibility: 4D

Specifications 

Main

 
RangeComPacT new generation
Product nameComPacT NSX new generation
device short nameNSX100F
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description4D
 3D + N/2
 3D
Neutral positionLeft
[In] rated current100 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelF 36 kA 415 V AC
Trip unit nameMicroLogic 2.2
Trip unit technologyElectronic
Trip unit protection functionsLSoI
control typeToggle
Circuit breaker mounting modeFixed
Complementary 
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability50000 cycles
Electrical durability50000 cycles at 440 V In/2
 30000 cycles at 440 V In
 20000 cycles at 690 V In/2
 10000 cycles at 690 V In
Power dissipation per pole4.7 W
mounting supportBackplate
Mounting positionHorizontal and vertical
 Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (long time)
 So : for short time short-circuit protection with fixed delay
 I : for instantaneous short-circuit protection
Trip unit rating100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range40...100 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
 16 s at 6 x Ir
 11 s at 7.2 x Ir
Neutral protection settings0.5 x Ir (3D + N/2)
 1 x Ir (4D)
 No protection (3D)
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5...10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1500 A
earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries5 slot(s)
Local signallingFlashing LED (green) for ready to operate
 LED 105 % Ir (red) for overload
 LED 90 % Ir (orange) for overload
Width (W)140 mm
Height (H)161 mm
Depth (D)86 mm

 

 

More Information
Weight2.400000
BrandSchneider Electric
ModelC10F42D100
Device ApplicationDistribution
Depth [cm]8.6
Width [cm]14
Height [cm]16.1
RangeNSX
FamilyPPCCB
TypeCircuit Breaker
Poles4P
[In] Rated Current100 A at 40 °C