The Schneider Electric LC1D80F7 Tesys D Contactor is a reliable 3-pole contactor designed to provide precise electrical circuit control. With an impressive 80A AC3 rating and a 110V AC 50-60 Hz coil, this contactor ensures dependable performance across a wide range of applications, from motor control to industrial equipment.
Key Features:
Versatile Control: Suitable for a broad spectrum of applications, including motor control and industrial machinery.
High Current Rating: With an 80A AC3 rating, it can effectively manage substantial electrical loads.
Sturdy Coil: The 110V AC coil with a 50-60 Hz frequency ensures consistent operation and control.
Product Specifications:
Pole Configuration: 3-Pole, 3 Normally Open (NO) Contacts
Rated Current: 80A AC3
Coil Voltage: 110V AC, 50-60 Hz
The Schneider Electric LC1D80F7 Tesys D Contactor offers a dependable and adaptable solution for your electrical control requirements. Whether you are controlling motors, lighting systems, or industrial machinery, this contactor guarantees robust performance and safety.
Specifications
Main | |
Range | TeSys |
Range of product | TeSys Deca |
Product or component type | Contactor |
Device short name | LC1D |
contactor application | Motor control |
Resistive load | |
utilisation category | AC-3 |
AC-3e | |
AC-4 | |
AC-1 | |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 300 V DC 25...400 Hz |
Power circuit: <= 690 V AC | |
[Ie] rated operational current | 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit | |
80 A (at <60 °C) at <= 440 V AC-3e for power circuit | |
[Uc] control circuit voltage | 110 V AC 50/60 Hz |
Complementary | |
Motor power kW | 22 kW at 220...230 V AC 50/60 Hz (AC-3) |
37 kW at 380...400 V AC 50/60 Hz (AC-3) | |
45 kW at 415...440 V AC 50/60 Hz (AC-3) | |
55 kW at 500 V AC 50/60 Hz (AC-3) | |
45 kW at 660...690 V AC 50/60 Hz (AC-3) | |
15 kW at 400 V AC 50/60 Hz (AC-4) | |
22 kW at 220...230 V AC 50/60 Hz (AC-3e) | |
37 kW at 380...400 V AC 50/60 Hz (AC-3e) | |
45 kW at 415...440 V AC 50/60 Hz (AC-3e) | |
55 kW at 500 V AC 50/60 Hz (AC-3e) | |
45 kW at 660...690 V AC 50/60 Hz (AC-3e) | |
Motor power hp | 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors |
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors | |
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors | |
30 hp at 230/240 V AC 50/60 Hz for 3 phases motors | |
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors | |
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors | |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Contact compatibility | M11 |
Protective cover | With |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit |
125 A (at 60 °C) for power circuit | |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 |
250 A DC for signalling circuit conforming to IEC 60947-5-1 | |
1100 A at 440 V for power circuit conforming to IEC 60947 | |
Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 640 A 40 °C - 10 s for power circuit |
990 A 40 °C - 1 s for power circuit | |
135 A 40 °C - 10 min for power circuit | |
320 A 40 °C - 1 min for power circuit | |
100 A - 1 s for signalling circuit | |
120 A - 500 ms for signalling circuit | |
140 A - 100 ms for signalling circuit | |
Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
200 A gG at <= 690 V coordination type 1 for power circuit | |
160 A gG at <= 690 V coordination type 2 for power circuit | |
Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
Power dissipation per pole | 5.1 W AC-3 |
12.5 W AC-1 | |
5.1 W AC-3e | |
[Ui] rated insulation voltage | Power circuit: 600 V CSA certified |
Power circuit: 600 V UL certified | |
Power circuit: 1000 V conforming to IEC 60947-4-1 | |
Signalling circuit: 690 V conforming to IEC 60947-1 | |
Signalling circuit: 600 V CSA certified | |
Signalling circuit: 600 V UL certified | |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
Mechanical durability | 4 Mcycles |
Electrical durability | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V |
1.5 Mcycles 80 A AC-3 at Ue <= 440 V | |
1.5 Mcycles 80 A AC-3e at Ue <= 440 V | |
Control circuit type | AC at 50/60 Hz standard |
Coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz |
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz | |
0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz | |
1...1.1 Uc (55…70 °C):operational AC 50/60 Hz | |
Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 20 °C) |
245 VA 50 Hz cos phi 0.75 (at 20 °C) | |
Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 20 °C) |
26 VA 50 Hz cos phi 0.3 (at 20 °C) | |
Heat dissipation | 6…10 W at 50/60 Hz |
Operating time | 20...35 ms closing |
6...20 ms opening | |
Maximum operating rate | 3600 cyc/h 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end |
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end | |
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end | |
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end | |
Power circuit: connector 1 4…50 mm² - cable stiffness: flexible without cable end | |
Power circuit: connector 2 4…25 mm² - cable stiffness: flexible without cable end | |
Power circuit: connector 1 4…50 mm² - cable stiffness: flexible with cable end | |
Power circuit: connector 2 4…16 mm² - cable stiffness: flexible with cable end | |
Power circuit: connector 1 4…50 mm² - cable stiffness: solid without cable end | |
Power circuit: connector 2 4…25 mm² - cable stiffness: solid without cable end | |
Tightening torque | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm |
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 | |
Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm | |
Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | |
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 | |
Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
type mirror contact 1 NC conforming to IEC 60947-4-1 | |
Signalling circuit frequency | 25...400 Hz |
Minimum switching voltage | 17 V for signalling circuit |
Minimum switching current | 5 mA for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact |
1.5 ms on energisation between NC and NO contact | |
mounting support | Rail |
Plate | |
Environment | |
Standards | CSA C22.2 No 14 |
EN 60947-4-1 | |
EN 60947-5-1 | |
IEC 60947-4-1 | |
IEC 60947-5-1 | |
UL 508 | |
product certifications | GL |
RINA | |
BV | |
DNV | |
LROS (Lloyds register of shipping) | |
CCC | |
GOST | |
UL | |
CSA | |
IP degree of protection | IP20 front face conforming to IEC 60529 |
Protective treatment | TH conforming to IEC 60068-2-30 |
Climatic withstand | Conforming to IACS E10 exposure to damp heat |
Permissible ambient air temperature around the device | -40…60 °C |
60…70 °C with derating | |
Operating altitude | 0...3000 m |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) |
Shocks contactor open (8 Gn for 11 ms) | |
Vibrations contactor closed (3 Gn, 5...300 Hz) | |
Shocks contactor closed (10 Gn for 11 ms) | |
height | 127 mm |
Width | 85 mm |
Depth | 130 mm |
Net weight | 1.59 kg |