Schneider Electric Variable Speed Drive ATV930, 18.5 kW, 400-480V, With Braking Unit, IP21

In stock
SKU
ATV930D18N4
Special Price EGP 186,319 Regular Price EGP 338,762

Description

The ATV930D18N4 Variable Speed Drive ATV930 is a powerful solution for applications that require precise control over motor speed. With a power rating of 18.5 kW and compatibility with 400-480V power systems, this drive is suitable for a wide range of industrial applications. Equipped with a braking unit, it allows for efficient control of deceleration and braking. The IP21 protection rating ensures the drive's durability and safety.

 

Key Features:

Precise Control: This drive enables precise control over motor speed, making it ideal for various industrial applications.

Braking Unit: Equipped with a braking unit, providing efficient control over deceleration and braking processes.

Compatibility: Designed for use with 400-480V power systems, ensuring versatility in different industrial settings.

Durable Design: The drive features an IP21 protection rating, enhancing its durability and safety.

 

Technical Specifications:

Product Type: Variable Speed Drive

Power Rating: 18.5 kW

Voltage Rating: 400-480V

Braking Unit: Included

Protection Rating: IP21

 

Specifications  

Main

 
Range of product Altivar Process ATV900
Device application Industrial application
Product or component type Variable speed drive
Product destination Asynchronous motors
  Synchronous motors
Product specific application Process for industrial
Variant With braking chopper
  Standard version
Network number of phases 3 phases
Mounting mode Wall mount
Communication port protocol Modbus TCP
  EtherNet/IP
  Modbus serial
[Us] rated supply voltage 380...480 V - 15...10 %
Motor power kW 18.5 kW for normal duty
  15.0 kW for heavy duty
Continuous output current 39.2 A at 4 kHz for normal duty
  31.7 A at 4 kHz for heavy duty
EMC filter Integrated
  With EMC plate option
IP degree of protection IP21
Degree of protection UL type 1
option module Slot A: communication module for Profibus DP V1
  Slot A: communication module for PROFINET
  Slot A: communication module for DeviceNet
  Slot A: communication module for EtherCAT
  Slot A: communication module for CANopen daisy chain RJ45
  Slot A: communication module for CANopen SUB-D 9
  Slot A: communication module for CANopen screw terminals
  Slot A/slot B/slot C: digital and analog I/O extension module
  Slot A/slot B/slot C: output relay extension module
  Slot B: 5/12 V digital encoder interface module
  Slot B: analog encoder interface module
  Slot B: resolver encoder interface module
  communication module for Ethernet Powerlink
Discrete input logic 16 preset speeds
Asynchronous motor control profile Constant torque standard
  Variable torque standard
  Optimized torque mode
Synchronous motor control profile Permanent magnet motor
  Synchronous reluctance motor
Maximum output frequency 599 Hz
Switching frequency 2...16 kHz adjustable
  4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Line current 33.4 A at 380 V (normal duty)
  27.7 A at 380 V (heavy duty)
  28.9 A at 480 V (normal duty)
  24.4 A at 480 V (heavy duty)
Apparent power 24 kVA at 480 V (normal duty)
  20.3 kVA at 480 V (heavy duty)
Maximum transient current 47 A during 60 s (normal duty)
  47.6 A during 60 s (heavy duty)
Network frequency 50...60 Hz
Prospective line Isc 50 kA
Complementary  
Discrete input number ١٠
Discrete input type DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
  DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
  STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
Discrete output number ٢
Discrete output type Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
  Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
  Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
analogue input number ٣
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
  AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
analogue output number ٢
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
  Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output number ٣
Relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
  Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles
  Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles
Maximum switching current Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC
  Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC
  Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
  Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
  Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC
  Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC
  Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
  Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Physical interface Ethernet
  2-wire RS 485
Connector type 2 RJ45
  1 RJ45
Method of access Slave Modbus TCP
Transmission rate 10, 100 Mbits
  4.8 kbps
  9600 bit/s
  19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible TRUE
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Motor slip compensation Adjustable
  Automatic whatever the load
  Not available in permanent magnet motor law
  Can be suppressed
Braking to standstill By DC injection
Brake chopper integrated TRUE
Maximum input current 33.4 A
Maximum output voltage 480.0 V
Relative symmetric network frequency tolerance 5%
Base load current at high overload 31.7 A
Base load current at low overload 39.2 A
Power dissipation in W Natural convection: 67 W at 380 V, switching frequency 4 kHz
  Forced convection: 460 W at 380 V, switching frequency 4 kHz
With safety function Safely Limited Speed (SLS) TRUE
With safety function Safe brake management (SBC/SBT) TRUE
With safety function Safe Operating Stop (SOS) FALSE
With safety function Safe Position (SP) FALSE
With safety function Safe programmable logic FALSE
With safety function Safe Speed Monitor (SSM) FALSE
With safety function Safe Stop 1 (SS1) TRUE
With sft fct Safe Stop 2 (SS2) FALSE
With safety function Safe torque off (STO) TRUE
With safety function Safely Limited Position (SLP) FALSE
With safety function Safe Direction (SDI) FALSE
Protection type Thermal protection: motor
  Safe torque off: motor
  Motor phase break: motor
  Thermal protection: drive
  Safe torque off: drive
  Overheating: drive
  Overcurrent between output phases and earth: drive
  Overload of output voltage: drive
  Short-circuit protection: drive
  Motor phase break: drive
  Overvoltages on the DC bus: drive
  Line supply overvoltage: drive
  Line supply undervoltage: drive
  Line supply phase loss: drive
  Overspeed: drive
  Break on the control circuit: drive
Quantity per set 1
Width 211 mm
height 545.9 mm
Depth 235 mm
Net weight 14.2 kg
Electrical connection Control: screw terminal 0.5...1.5 mm²/AWG 20...AWG 16
  Line side: screw terminal 10...16 mm²/AWG 8...AWG 6
  Motor: screw terminal 10...16 mm²/AWG 8...AWG 6
  DC bus: screw terminal 10...16 mm²/AWG 8...AWG 6
Transmission rate 10/100 Mbit/s for Ethernet IP/Modbus TCP
  4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity for Modbus serial
Type of polarization No impedance for Modbus serial
Number of addresses 1…247 for Modbus serial
Supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
  Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
  Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling Local diagnostic: 3 LED (mono/dual colour)
  Embedded communication status: 5 LED (dual colour)
  Communication module status: 2 LED (dual colour)
  Presence of voltage: 1 LED (red)
Input compatibility DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2
  DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68
  STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
  Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
  Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1)
  Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Sampling duration 2 ms +/- 0.5 ms (DI1...DI8) - discrete input
  5 ms +/- 1 ms (DI7, DI8) - pulse input
  1 ms +/- 1 ms (AI1, AI2, AI3) - analog input
  5 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
  +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
  AQ1, AQ2: +/- 0.2 % for analog output
Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Isolation Between power and control terminals
Environment  
Operating altitude <= 1000 m without derating
  1000...4800 m with current derating 1 % per 100 m
Operating position Vertical +/- 10 degree
product certifications UL
  TÜV
  CSA
Marking CE
standards UL 508C
  EN/IEC 61800-3
  EN/IEC 61800-5-1
  IEC 61000-3-12
  IEC 60721-3
  IEC 61508
  IEC 13849-1
Maximum THDI <48 % from 80...100 % of load conforming to IEC 61000-3-12
Assembly style Enclosed
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
  Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
  Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
  1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
  Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
  Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Volume of cooling air 215 m3/h
Overvoltage category III
Regulation loop Adjustable PID regulator
Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Noise level 59.5 dB conforming to 86/188/EEC
Vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
  1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
  Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation -15…50 °C (without derating)
  50…60 °C (with derating factor)
Noise level 59.5 dB
Pollution degree 2
Ambient air transport temperature -40…70 °C
Ambient air temperature for storage -40…70 °C

 

 

Specifications

More Information
Weight 14.200000
Brand Schneider Electric
Model ATV930D18N4
Width [cm] 21.1
Height [cm] 54.59
Range ATV930
Family IDVSD

Reviews

You're reviewing:

Schneider Electric Variable Speed Drive ATV930, 18.5 kW, 400-480V, With Braking Unit, IP21