The GV2LE05 TeSys GV2 Motor Circuit Breaker is an essential component for motor protection and control in industrial settings. With three poles and a current rating of 1A, this circuit breaker offers versatile protection for motors of various sizes. It features a magnetic trip unit for reliable disconnection during overloads or short-circuit conditions and secure screw clamp terminals for dependable electrical connections.
Key Features:
Motor Protection: Engineered to safeguard motors against overloads and short-circuit conditions, the TeSys GV2 Motor Circuit Breaker ensures the longevity and reliability of your electrical systems.
Three Poles: Equipped with three poles, this circuit breaker provides enhanced protection for a wide range of motor sizes, making it suitable for diverse industrial applications.
Magnetic Trip Unit: The magnetic trip unit ensures consistent disconnection in the presence of overloads and short circuits, preventing equipment damage.
Toggle Control: The toggle control allows for easy manual operation and control of the circuit breaker.
Screw Clamp Terminals: Secure screw clamp terminals guarantee dependable electrical connections, reducing the need for frequent maintenance.
Technical Specifications:
Product Type: Motor Circuit Breaker
Poles: 3P (Three Poles)
Current Rating: 1A
Trip Unit: Magnetic
Terminals: Screw Clamp Terminals
Specifications |
|
Main |
|
Range | TeSys Deca |
Product name | TeSys GV2 |
Product or component type | Motor circuit breaker |
device short name | GV2LE |
Device application | Motor protection |
Trip unit technology | Magnetic |
Complementary | |
Poles description | 3P |
Network type | AC |
Utilisation category | Category A conforming to IEC 60947-2 |
AC-3 conforming to IEC 60947-4-1 | |
Network frequency | 50/60 Hz conforming to IEC 60947-2 |
Fixing mode | 35 mm symmetrical DIN rail: clipped |
Panel: screwed (with adaptor plate) | |
Motor power kW | 0.25 kW at 400/415 V AC 50/60 Hz |
0.37 kW at 400/415 V AC 50/60 Hz | |
0.37 kW at 500 V AC 50/60 Hz | |
0.55 kW at 690 V AC 50/60 Hz | |
0.75 kW at 690 V AC 50/60 Hz | |
Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
control type | Toggle |
[In] rated current | 0.041666667 |