The Schneider Electric XA2ET42 is a red emergency switching-off pushbutton with a non-trigger, push-pull design. It features 1 normally closed (1NC) contact. This pushbutton is specifically designed for use in emergency stop applications, providing a quick and reliable means to disconnect power or machinery in case of an emergency. The red color and clear markings make it easily identifiable as an emergency switch.
Key Features:
Red Pushbutton: The red color is universally recognized as the color of emergency stop controls.
Non-Trigger, Push-Pull Design: The push-pull design ensures quick and reliable operation.
1NC Contact: Equipped with one normally closed contact for electrical connections.
Emergency Stop Function: Ideal for use as an emergency stop button to quickly disconnect power in critical situations.
Clear Markings: Marked for easy identification as an emergency switching-off pushbutton.
Versatile Applications: Suitable for a wide range of emergency stop applications.
Specifications | |
Main |
|
Range of product | Easy Harmony XA2 |
Product or component type | Complete emergency switching off push-button |
Device short name | XA2 |
bezel material | Plastic |
Mounting diameter | 22.5 mm |
Complementary | |
Operating position | Any position |
Device mounting | Fixing hole - diameter: 22 mm |
Fixing center | >= 30 x 40 mm (panel) - thickness: 1…5 mm |
Shape of signaling unit head | Round |
Type of operator | Push-pull |
Reset | Push-pull |
Operator profile | Red mushroom Ø 40 mm |
Cap/operator or lens colour | Red |
Contacts type and composition | 1 NC |
contact operation | Slow-break |
Positive opening | With NC contact |
Mechanical durability | 100000 cycles |
Connections - terminals | Screw clamp terminal, <= 2 x 1.5 mm² |
Screw clamp terminal, <= 1 x 2.5 mm² | |
Screw clamp terminal, >= 1 x 0.5 mm² | |
Faston terminals, connection size: 6.3 mm | |
Tightening torque | 0.8 N.m |
Short-circuit protection | 10 A gL fuse conforming to IEC 60269-1 |
[Ui] rated insulation voltage | 600 V conforming to IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
[Ie] rated operational current | 3 A at 240 V, AC-15, A600 |
0.27 A at 250 V, DC-13, Q600 | |
Electrical durability | 500000 cycles, AC-15, 3 A at 230 V, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-4 |
500000 cycles, DC-13, 0.2 A at 110 V, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-4 | |
Electrical reliability | Λ < 10exp(-8) at 24 V |
height | 30 mm |
Width | 42 mm |
Depth | 74.2 mm |
Net weight | 0.088 kg |
Type of operator | Mechanical latching |
Environment | |
Protective treatment | TC |
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -25…55 °C |
Overvoltage category | Class I conforming to IEC 536 |
IP degree of protection | IP65 conforming to IEC 60068-2-27 |
IK degree of protection | IK03 |
standards | GB 14048.5 |
IEC 60947-1 | |
IEC 60947-5-1 | |
GB 14048.1 | |
IEC 60529 |