The RXM2AB1P7 relay from Schneider Electric is a reliable miniature control device designed to meet the switching and control requirements of alternating current circuits. This relay comes with a 2CO (two-pole double throw) configuration, allowing you to control two different directions in your circuit. With a current rating of 12A and an operating voltage of 230V AC, this relay is suitable for a variety of industrial and commercial applications.
Key Features:
2CO Configuration: This relay enables you to control two different directions in your circuit.
12A Current Rating: With a 12A current rating, it can handle moderate to large electrical loads.
230V AC Operating Voltage: The 230V AC operating voltage provides versatility in usage and makes it suitable for various systems.
Miniature Design: It can be easily installed in confined spaces on control panels.
Technical Specifications:
Contact Configuration: 2CO (Two-Pole Double Throw)
Current Rating: 12A
Operating Voltage: 230V AC
Specifications
Main | |
Range of product | Harmony Electromechanical Relays |
Series name | Miniature |
Product or component type | Plug-in relay |
device short name | RXM |
Contacts type and composition | 2 C/O |
[Uc] control circuit voltage | 230 V AC 50/60 Hz |
Status LED | Without |
control type | Lockable test button |
Utilisation coefficient | 20% |
Complementary | |
Shape of pin | Flat |
[Ui] rated insulation voltage | 250 V conforming to IEC |
300 V conforming to CSA | |
300 V conforming to UL | |
[Uimp] rated impulse withstand voltage | 4 kV during 1.2/50 µs |
Contacts material | AgNi |
[Ie] rated operational current | 12 A at 28 V (DC) NO conforming to IEC |
12 A at 250 V (AC) NO conforming to IEC | |
6 A at 28 V (DC) NC conforming to IEC | |
6 A at 250 V (AC) NC conforming to IEC | |
12 A at 28 V (DC) conforming to UL | |
12 A at 277 V (AC) conforming to UL | |
Continuous output current | 10:00 ص |
Maximum switching voltage | 250 V conforming to IEC |
resistive rated load | 12 A at 250 V AC |
12 A at 28 V DC | |
Maximum switching capacity | 3000 VA/336 W |
Minimum switching capacity | 170 mW at 10 mA, 17 V |
Operating rate | <= 1200 cycles/hour under load |
<= 18000 cycles/hour no-load | |
Mechanical durability | 10000000 cycles |
Electrical durability | 100000 cycles for resistive load |
average coil consumption in VA | 1.2 at 60 Hz |
Average consumption | 1.2 VA at 60 Hz |
Drop-out voltage threshold | >= 0.15 Uc |
operate time | 20 ms |
release time | 20 ms |
average coil resistance | 15000 Ohm at 20 °C +/- 15 % |
Rated operational voltage limits | 184...253 V AC |
Safety reliability data | B10d = 100000 |
Protection category | RT I |
Test levels | Level A group mounting |
Operating position | Any position |
Net weight | 0.037 kg |
Device presentation | Complete product |
Environment | |
Dielectric strength | 1300 V AC between contacts with micro disconnection |
2000 V AC between coil and contact with basic insulation | |
2000 V AC between poles with basic insulation | |
product certifications | CSA |
UL | |
GOST | |
Lloyd's | |
CE | |
standards | IEC 61810-1 |
UL 508 | |
CSA C22.2 No 14 | |
Ambient air temperature for storage | -40…85 °C |
Ambient air temperature for operation | -40…55 °C |
Vibration resistance | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation |
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating | |
IP degree of protection | IP40 conforming to IEC 60529 |
Shock resistance | 10 gn for in operation |
30 gn for not operating | |
Pollution degree | 3 |