The Schneider Electric XB4BK123B5 Illuminated Selector Switch is an essential component of control and signaling systems in industrial applications. This switch features a green metal design with a 22mm diameter. It provides a 2-position stay-put functionality, meaning it remains in the selected position. It operates at 24V AC/DC and comes with 1 Normally Open (NO) and 1 Normally Closed (NC) contact. This makes it suitable for multiple control and signaling functions in industrial environments.
Key Features:
Illuminated Selector Switch: A green illuminated selector switch enhances visibility and control.
2-Position Stay-Put: Offers two stable positions for reliable control.
Voltage Compatibility: Operates at 24V AC/DC for versatile usage.
Contacts: Features 1 Normally Open (NO) and 1 Normally Closed (NC) contact.
Product Specifications:
Type: Illuminated Selector Switch
Color: Green
Diameter: 22mm
Positions: 2-Position (Stay-Put)
Voltage: 24V AC/DC
Contacts: 1 Normally Open (NO) + 1 Normally Closed (NC)
Specifications
Main | |
Range of product | Harmony XB4 |
Product or component type | Illuminated selector switch |
Device short name | XB4 |
bezel material | Chromium plated metal |
Fixing collar material | Zamak |
Head type | Standard |
Mounting diameter | 22 mm |
Sale per indivisible quantity | 1 |
Shape of signaling unit head | Round |
Type of operator | Stay put |
Operator profile | Green standard handle |
Operator position information | 2 positions 90° |
Contacts type and composition | 1 NO + 1 NC |
contact operation | Slow-break |
Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1 |
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1 | |
Light source | Universal LED |
Bulb base | Integral LED |
[Us] rated supply voltage | 24 V AC/DC at 50/60 Hz |
Complementary | |
height | 47 mm |
Width | 30 mm |
Depth | 68 mm |
Terminals description ISO n°1 | (13-14)NO |
(21-22)NC | |
Net weight | 0.111 kg |
Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
contacts usage | Standard contacts |
Positive opening | With conforming to IEC 60947-5-1 appendix K |
Operating torque | 0.14 N.m NO changing electrical state |
Mechanical durability | 1000000 cycles |
Tightening torque | 0.8…1.2 N.m conforming to IEC 60947-1 |
Shape of screw head | Cross compatible with Philips no 1 screwdriver |
Cross compatible with pozidriv No 1 screwdriver | |
Slotted compatible with flat Ø 4 mm screwdriver | |
Slotted compatible with flat Ø 5.5 mm screwdriver | |
Contacts material | Silver alloy (Ag/Ni) |
Short-circuit protection | 10 A cartridge fuse type gG conforming to IEC 60947-5-1 |
[Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
[Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
[Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 |
6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 | |
0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 | |
0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 | |
0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 | |
1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 | |
Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C |
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | |
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | |
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | |
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | |
Electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4 |
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to IEC 60947-5-4 | |
Signalling type | Steady |
Supply voltage limits | 19.2…30 V DC |
21.6…26.4 V AC | |
Current consumption | 18 mA |
Service life | 100000 h at rated voltage and 25 °C |
Surge withstand | 1 kV conforming to IEC 61000-4-5 |
Device presentation | Complete product |
Environment | |
Protective treatment | TH |
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -40…70 °C |
Electrical shock protection class | Class I conforming to IEC 60536 |
IP degree of protection | IP66 conforming to IEC 60529 |
IP67 | |
IP69 | |
IP69K | |
NEMA degree of protection | NEMA 13 |
NEMA 4X | |
IK degree of protection | IK04 conforming to IEC 50102 |
standards | IEC 60947-5-4 |
IEC 60947-1 | |
UL 508 | |
IEC 60947-5-1 | |
CSA C22.2 No 14 | |
IEC 60947-5-5 | |
JIS C8201-5-1 | |
JIS C8201-1 | |
product certifications | DNV |
LROS (Lloyds register of shipping) | |
GL | |
BV | |
CSA | |
UL | |
Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | |
Resistance to fast transients | 2 kV conforming to IEC 61000-4-4 |
Resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 |
Resistance to electrostatic discharge | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 |
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | |
Electromagnetic emission | Class B conforming to IEC 55011 |