The XB4BS9442 Emergency Stop Switch by Schneider Electric is designed for safety-critical applications where immediate equipment or process shutdown is required. It features a large 40mm red mushroom-shaped button for easy recognition and operation. This switch is equipped with a trigger latching mechanism and a key release for added safety measures. It includes one normally closed (NC) contact for electrical interruption when activated.
Product Features:
Emergency Stop Function: Provides an immediate and effective means to halt machinery or processes in emergency situations.
40mm Mushroom Head: The large button is easy to identify and operate.
Trigger Latching Mechanism: Allows the switch to stay engaged when triggered.
Key Release: For unlocking the switch, simply use the provided key.
1 Normally Closed (NC) Contact: Provides electrical interruption when the switch is activated.
Durable and Reliable: Designed to withstand tough industrial environments.
Product Specifications:
Button Type: Mushroom-shaped
Button Diameter: 40mm
Locking Type: Trigger latching
Release Type: Key release
Contact Type: 1 Normally Closed (NC)
Color: Red
Material: Metal
Industrial Use: Yes
Specifications
Main | |
Range of product | Harmony XB4 |
Product or component type | Emergency stop push-button |
Emergency switching off push-button | |
device short name | XB4 |
bezel material | Chromium plated metal |
Fixing collar material | Zamak |
Mounting diameter | 22 mm |
Sale per indivisible quantity | 1 |
Shape of signaling unit head | Round |
Type of operator | Trigger action and mechanical latching |
Head type | Standard |
Reset | Key release |
Operator profile | Red mushroom Ø 40 mm, unmarked |
Type of keylock | Key 455 |
Key withdrawal position | Center |
contact operation | Slow-break |
Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1 |
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1 | |
Complementary | |
height | 47 mm |
Width | 40 mm |
Depth | 104 mm |
Terminals description ISO n°1 | (21-22)NC |
Net weight | 0.133 kg |
Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
contacts usage | Standard contacts |
Positive opening | With conforming to IEC 60947-5-1 appendix K |
Operating travel | 1.5 mm (NC changing electrical state) |
4.3 mm (total travel) | |
Mechanical durability | 300000 cycles |
Tightening torque | 0.8…1.2 N.m conforming to IEC 60947-1 |
Shape of screw head | Cross compatible with Philips no 1 screwdriver |
Cross compatible with pozidriv No 1 screwdriver | |
Slotted compatible with flat Ø 4 mm screwdriver | |
Slotted compatible with flat Ø 5.5 mm screwdriver | |
Contacts material | Silver alloy (Ag/Ni) |
Short-circuit protection | 10 A cartridge fuse type gG conforming to IEC 60947-5-1 |
[Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
[Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
[Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 |
6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 | |
0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 | |
0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 | |
0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 | |
1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 | |
Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
Electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4 |
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to IEC 60947-5-4 | |
Device presentation | Complete product |
Environment | |
Protective treatment | TH |
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -40…70 °C |
Electrical shock protection class | Class I conforming to IEC 60536 |
IP degree of protection | IP66 conforming to IEC 60529 |
IP67 | |
IP69 | |
IP69K | |
NEMA degree of protection | NEMA 13 |
NEMA 4X | |
IK degree of protection | IK03 conforming to IEC 50102 |
standards | IEC 60947-1 |
IEC 60947-5-5 | |
JIS C8201-5-1 | |
IEC 60947-5-4 | |
IEC 60364-5-53 | |
IEC 60204-1 | |
UL 508 | |
IEC 60947-5-1 | |
CSA C22.2 No 14 | |
ISO 13850 | |
JIS C8201-1 | |
product certifications | CSA |
LROS (Lloyds register of shipping) | |
DNV | |
BV | |
UL listed | |
GL | |
Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |