FXM250 is a complete manual source changeover assembly for two Compact INS250 3 poles switch disconnectors. It provides an easy way to implement source changeover functions with small size,taking up less room in the switchboard. The operational current is 250A at 690VAC 50/60Hz,in categories AC22A/AC23A. The operational current is 250A at 125VDC (2 poles in series) or at 250VDC (4 poles in series),in categories DC22A/DC23A. There is a single 3 position rotary handle that controls the two switch disconnectors (normal source ON,OFF,replacement source ON). A complete source changeover assembly can be ordered with a single catalogue number. A complete source changeover assembly can be ordered with a single catalogue number.
Specifications | |
Main |
|
Range of product | INS250 |
Range | TransferPacT |
ComPact | |
device short name | INS250 |
Product or component type | Manual transfer switch |
Device application | Change source of supply |
Range compatibility | ComPact ComPacT INS INS250 switch disconnector |
Poles description | 3P |
Network type | AC |
DC | |
Network frequency | 50/60 Hz |
Mounting mode | Fixed |
Upside connection | Front |
downside connection | Front |
Suitability for isolation | Yes |
Contact position indicator | Yes |
[Icm] rated short-circuit making capacity | 30 kA switch-disconnector alone 690 V AC at 50/60 Hz |
330 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz | |
Complementary | |
transfer switch class | PC |
Number of contact position | 3 |
control type | Direct front rotary handle |
Operating mode | Manual |
mounting support | Rail |
Plate | |
Locking options description | Padlocking in OFF position |
[Ie] rated operational current | AC-22A: 250 A AC 50/60 Hz 220/240 V |
AC-22A: 250 A AC 50/60 Hz 380/415 V | |
AC-22A: 250 A AC 50/60 Hz 440/480 V | |
AC-22A: 250 A AC 50/60 Hz 500/525 V | |
AC-22A: 250 A AC 50/60 Hz 660/690 V | |
AC-23A: 250 A AC 50/60 Hz 220/240 V | |
AC-23A: 250 A AC 50/60 Hz 380/415 V | |
AC-23A: 250 A AC 50/60 Hz 440/480 V | |
AC-23A: 250 A AC 50/60 Hz 500/525 V | |
AC-23A: 250 A AC 50/60 Hz 660/690 V | |
DC-22A: 250 A DC 125 V 2 poles in series | |
DC-23A: 250 A DC 125 V 2 poles in series | |
[Ith] conventional free air thermal current | 250 A at 60 °C |
Rated duty | Uninterrupted |
Intermittent duty class | Class 120 - 60 % |
[Ui] rated insulation voltage | 750 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-3 |
125 V DC conforming to IEC 60947-3 | |
Mechanical interlocking | With mechanical interlocking |
Mechanical durability | 15000 cycles |
Electrical durability | AC-22A: 1500 cycles 440 V AC 50/60 Hz |
AC-22A: 1500 cycles 500 V AC 50/60 Hz | |
AC-22A: 1500 cycles 690 V AC 50/60 Hz | |
AC-23A: 1500 cycles 440 V AC 50/60 Hz | |
AC-23A: 1500 cycles 500 V AC 50/60 Hz | |
AC-23A: 1500 cycles 690 V AC 50/60 Hz | |
DC-22A: 1500 cycles 125 V DC 2 poles in series | |
DC-23A: 1500 cycles 125 V DC 2 poles in series | |
Connection pitch | 35 mm |
[Icw] rated short-time withstand current | 1.8 kA during 30 s conforming to IEC 60947-3 |
2.2 kA during 20 s conforming to IEC 60947-3 | |
4.9 kA during 3 s conforming to IEC 60947-3 | |
8.5 kA during 1 s conforming to IEC 60947-3 | |
height | 136 mm |
Width | 295 mm |
Depth | 131 mm |
Net weight | 6.4 kg |
Environment | |
standards | IEC 60947-1 |
IEC 60947-3 | |
product certifications | CB |
Electrical shock protection class | Class II |
IP degree of protection | IP40 conforming to IEC 60947-3 |
Pollution degree | 3 |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -50…85 °C |