Schneider Electric EasyPact EZC100N Circuit Breaker TMD 20A, 3 Poles (3D)

In stock
SKU
EZC100N3020
Special Price EGP 5,632 Regular Price EGP 8,162

Description

EasyPact EZC100N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings,offering good performance at competitive price The breaking capacity (Icu) is 15kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 20A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100N is compliant with international standards (IEC 60947,UL 508) and marine certifications.

 

Specifications  

Main

 
Range of product EasyPact
Product or component type Circuit breaker
device short name Easypact EZC100N
circuit breaker name Easypact EZC100N
Device application Distribution
Poles description 3P
Protected poles description 3t
Network type DC
  AC
Network frequency 50/60 Hz
[In] rated current 20 A at 40 °C
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
  250 V DC conforming to IEC 60947-2
Breaking capacity code N
Breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
  18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
  25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
  25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
  5 kA Icu at 125 V DC 1P conforming to IEC 60947-2
  5 kA Icu at 250 V DC 2P conforming to IEC 60947-2
  5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
  9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
  12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
  12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
  2.5 kA at 125 V DC conforming to IEC 60947-2
  2.5 kA at 250 V DC conforming to IEC 60947-2
  2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
  7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
utilisation category Category A
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 20 A at 50 °C
Protection type Short-circuit protection
  Overload protection
Pollution degree 3 conforming to IEC 60664-1
  3 conforming to IEC 947-1
Complementary  
control type Toggle
Mounting mode Fixed
mounting support Backplate
Upside connection Front
downside connection Front
Mechanical durability 8500 cycles
Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch 25 mm
Local signalling Positive contact indication
Neutral protection setting Without protection
earth-leakage protection Without
height 130 mm
Width 75 mm
Depth 60 mm
Environment  
standards EN/IEC 60947-1
  JIS C8201-2-2
  EN/IEC 60947-2
  GB/T 14048.2
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C

 

 

Specifications

More Information
Weight 0.825000
Brand Schneider Electric
Model EZC100N3020
Depth [cm] 6
Width [cm] 7.5
Height [cm] 13
Range EZC
Family PPCCB

Reviews

You're reviewing:

Schneider Electric EasyPact EZC100N Circuit Breaker TMD 20A, 3 Poles (3D)