Introducing the Schneider Electric XB4BVB4 Push Button – a versatile and reliable solution for your electrical control needs. This push button features a momentary design, providing effortless control. It's also equipped with illumination for clear status indication and operates with a 22mm mounting size.
Key Features:
Effortless Control: The XB4BVB4 push button offers momentary operation, making it ideal for applications where you need to activate or deactivate a function with a simple touch.
Illuminated Design: This push button features built-in illumination, ensuring you can easily see the status of your equipment or systems.
22mm Mounting: With a standard 22mm mounting size, it's compatible with a wide range of control panels and enclosures.
High-Quality Construction: Crafted with durable materials, this push button is built to withstand tough environments.
Technical Specifications:
Operation: Momentary
Illuminated: Yes
Mounting Size: 22mm
Specifications
Main | |
Range of product | Harmony XB4 |
Product or component type | Pilot light |
Device short name | XB4 |
bezel material | Chromium plated metal |
Fixing collar material | Zamak |
Mounting diameter | 22.5 mm |
Head type | Standard |
Sale per indivisible quantity | 1 |
Shape of signaling unit head | Round |
Cap/operator or lens colour | Red |
Operator additional information | With plain lens |
Light source | Universal LED |
Bulb base | Integral LED |
light source colour | Red |
[Us] rated supply voltage | 24 V AC/DC 50/60 Hz |
Complementary | |
height | 47 mm |
Width | 30 mm |
Depth | 54 mm |
Terminals description ISO n°1 | (X1-X2)PL |
Net weight | 0.08 kg |
Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1 |
Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1 | |
[Ui] rated insulation voltage | 250 V (pollution degree 3) conforming to EN 60947-1 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN 60947-1 |
Signalling type | Steady |
Current consumption | 18 mA |
Service life | 100000 h at rated voltage and 25 °C |
Surge withstand | 1 kV conforming to IEC 61000-4-5 |
Device presentation | Complete product |
Supply voltage limits | 19.2…30 V DC |
21.6…26.4 V AC | |
Environment | |
Protective treatment | TH |
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -40…70 °C |
Electrical shock protection class | Class I conforming to IEC 60536 |
IP degree of protection | IP66 conforming to IEC 60529 |
IP67 | |
IP69 | |
IP69K | |
NEMA degree of protection | NEMA 13 |
NEMA 4X | |
IK degree of protection | IK06 conforming to IEC 50102 |
standards | EN/IEC 60947-5-5 |
EN/IEC 60947-5-4 | |
JIS C8201-5-1 | |
EN/IEC 60947-5-1 | |
EN/IEC 60947-1 | |
CSA C22.2 No 14 | |
UL 508 | |
JIS C8201-1 | |
product certifications | CSA |
UL listed | |
Vibration resistance | 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | |
Resistance to fast transients | 2 kV conforming to IEC 61000-4-4 |
Resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 |
Resistance to electrostatic discharge | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 |
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | |
Electromagnetic emission | Class B conforming to IEC 55011 |