The Schneider Electric RM35TF30 is a versatile multifunction phase control relay belonging to the RM35T range.
It is designed to monitor and control various aspects of electrical systems in industrial and commercial settings, offering a wide range of applications and ensuring the safety and efficiency of your electrical installations.
Key Features:
Voltage Monitoring: The RM35TF30 relay is suitable for monitoring voltages in the range of 194-528V AC. It offers precision and reliability in voltage control, ensuring the stability of your electrical systems.
Multifunctional: This relay is capable of performing various functions, including phase control and monitoring, ensuring that electrical systems are functioning correctly and safely.
Versatile Applications: The RM35TF30 is well-suited for a variety of applications, such as motor control, industrial machinery, and HVAC systems. Its adaptability makes it a valuable component in electrical installations.
High-Quality Design: Schneider Electric is a trusted brand known for delivering high-quality electrical components. The RM35TF30 reflects this commitment to quality and reliability.
This multifunction phase control relay is an essential component for maintaining the efficiency and safety of electrical systems. Its wide voltage range and multifunction capabilities make it a valuable asset in various industrial and commercial settings.
Technical Specifications:
Voltage Range: 24-240V AC/DC
Contacts: 2 NO (Normally Open) Contacts
Specifications
Main | |
Range of product | Harmony Control Relays |
Product or component type | 3-phase control relay |
Relay type | Multifunction control relay |
Product specific application | For 3-phase supply |
Relay name | RM35TF |
Relay monitored parameters | Undervoltage and overvoltage in window mode |
Phase sequence | |
Phase failure detection | |
Asymmetry | |
time delay | Adjustable 0.1...10 s, +/- 10 % of the full scale value |
Switching capacity in VA | 1250 VA |
Measurement range | 220...480 V voltage AC |
Contacts type and composition | 2 C/O |
[Uc] control circuit voltage | 220...480 V |
Complementary | |
Reset time | 1500 ms at 480 V |
Maximum switching voltage | 250 V AC |
250 V DC | |
Minimum switching current | 10 mA at 5 V DC |
Maximum switching current | 5 A AC |
5 A DC | |
Supply voltage limits | 194…528 V AC, 3 phases |
Control circuit voltage limits | - 12 % + 10 % Un |
Power consumption in VA | 0…22 VA at 400 V AC 50 Hz |
Voltage detection threshold | < 194 V |
control circuit frequency | 50...60 Hz +/- 10 % |
Output contacts | 2 C/O |
Nominal output current | 05:00 ص |
Measurement voltage limits | 176…528 V AC |
Hysteresis | 2% |
delay at power up | 650 ms |
Maximum measuring cycle | 140 ms measurement cycle as true rms value |
Threshold adjustment voltage | -20...-2 % in the range 380...480 V AC |
2...20 % of Un selected | |
-12...-2 % in the range 220 V AC | |
+2...+20 % in the range 220...440 V AC | |
+2...+10 % in the range 480 V AC | |
Voltage range | 220...480 V phase to phase |
Adjustment of asymmetry threshold | 5...15 % of Un selected |
Repeat accuracy | 0.3 % for time delay |
0.5 % for input and measurement circuit | |
Measurement error | < 1 % over the whole range with voltage variation |
0.05 %/°C with temperature variation | |
Response time | < 200 ms (in the event of a fault) |
Marking | CE |
Overvoltage category | III conforming to IEC 60664-1 |
Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 |
> 500 MOhm at 500 V DC conforming to IEC 60664-1 | |
[Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
Supply frequency | 50/60 Hz +/- 10 % |
Operating position | Any position without derating |
Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end |
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end | |
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end | |
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end | |
Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
Housing material | Self-extinguishing plastic |
Local signalling | LED (green) for power ON |
LED (yellow) for relay ON | |
LED (yellow) for fault | |
Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
Electrical durability | 100000 cycles |
Mechanical durability | 30000000 cycles |
Operating rate | <= 360 operations/hour full load |
Utilisation category | AC-12 conforming to IEC 60947-5-1 |
AC-13 conforming to IEC 60947-5-1 | |
AC-14 conforming to IEC 60947-5-1 | |
AC-15 conforming to IEC 60947-5-1 | |
DC-12 conforming to IEC 60947-5-1 | |
DC-13 conforming to IEC 60947-5-1 | |
Safety reliability data | MTTFd = 399.5 years |
B10d = 360000 | |
Width | 35 mm |
Net weight | 0.13 kg |
Environment | |
Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 |
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 | |
Immunity for industrial environments conforming to IEC 61000-6-2 | |
standards | IEC 60255-1 |
product certifications | GL |
UL | |
CSA | |
GOST | |
C-Tick | |
Directives | 89/336/EEC - electromagnetic compatibility |
73/23/EEC - low voltage directive | |
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -20…50 °C |
Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 |
1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 | |
Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
IP degree of protection | IP20 (terminals) conforming to IEC 60529 |
IP30 (casing) conforming to IEC 60529 | |
Pollution degree | 3 conforming to IEC 60664-1 |
Dielectric test voltage | 2 kV, 1 min AC 50 Hz |