SpaceLogic MP-C Controller is a multi-purpose, fully programmable, IP based field controller ideal for plant room HVAC control. The MP-C models offer a flexible mix of I/O point types that suit a wide range of HVAC applications. It can be used as a standalone BACnet/IP controller or as part of an EcoStruxure BMS with a SpaceLogic AS-P or AS-B server or an Enterprise Server. The MP-C models support an optional display that provides insight and control of the inputs and outputs. The MP-C-18A has 10 Universal I/O Type Ub, 4 DO Triacs, 3 Form A Relays and 1 HP Relay I/O point. It supports the SpaceLogic IP-IO Expansion Modules for extended I/O point count. Its dimensions are 110 mm (4.3 in.) in height, 153 mm (6.0 in.) in width and 64 mm (2.5 in.) in depth. It is a UL 916 (Open Class Energy Management Equipment) listed product for the United States and Canada - UL file E80146. The device can be mounted in a DIN rail or other flat surface inside a cabinet. Available spare parts are terminal blocks (SXWMPCCON10001), DIN-RAIL-CLIP/end clip (SXWDINEND10001), eCommission Bluetooth Adapter (SXWBTAECXX10001).
Specifications:
Main |
|
Maximum number of I/O expansion module |
3 |
Device application |
Low voltage fan coil |
Low voltage heat pump |
|
Product or component type |
Field controller |
Device short name |
MP-C-18A |
Function available |
Programmable |
Smart sensor input |
|
Topology |
Star |
Daisy chain |
|
Rapid Spanning Tree Protocol (RSTP) |
|
Model |
MP-C-18A |
Network frequency |
50 Hz |
60 Hz |
|
Width |
153 mm |
mounting mode |
DIN rail mount |
Panel-mounted |
|
Product certifications |
RCM |
CE |
|
cUL listed |
|
UL listed |
|
maximum power consumption in W |
12 W |
Power consumption in VA |
22 VA |
ambient air temperature for storage |
-40…70 °C |
Clock drift |
+/- 1 min/month |
IP degree of protection |
IP20 |
Input/output type |
10 universal I/O |
Input voltage |
-0.5...24 V DC for universal input |
Memory type |
123 kB backup |
32 MB flash |
|
128 MB RAM |
|
Communication port support |
ETHERNET 10/100BASE-TX |
[Us] rated supply voltage |
24 V AC +/- 20 % |
24...30 V DC |
|
21...33 V DC |
|
Number of outputs |
4 triac output |
3 form A relay output |
|
1 relay output |
|
Depth |
64 mm |
Protection type |
MOV suppression |
Internal fuse |
|
Output voltage |
250 V AC,12 A for high power relay output |
24 V DC,12 A for high power relay output |
|
250 V AC,2 A for form A relay output |
|
30 V DC,2 A for form A relay output |
|
-0.5...24 V DC for universal output |
|
24 V AC for triac output |
|
Output current |
0.5 A max triac output |
Number of port |
2, connector type: RJ45 |
1, connector type: USB type A female |
|
1, connector type: USB device port Mini-B |
|
Complementary |
|
Backup time |
7 days |
Flame retardance |
UL94-5V |
Communication port protocol |
BACnet IP |
Standards |
UL 916 |
ICES-003 |
|
EN 61000-6-2 |
|
EN 50491-5-3 |
|
EN 60730-1 |
|
EN 60730-2-11 |
|
EN 50491-3 |
|
EN 61000-6-3 |
|
EN 50491-5-2 |
|
FCC part 15 Subpart B class B |
|
Range compatibility |
SpaceLogic IP controller |