Introducing the RE22R1DMR Modular Timing Relay by Schneider Electric, a versatile and precise timing solution designed to meet the demands of various industrial applications.
This relay provides reliable timing control for your operations, offering a time delay range from 0.05 seconds to 300 hours.
Key Features:
Modular Design: The modular design of the RE22R1DMR ensures easy installation and integration into your control systems.
Wide Time Delay Range: With a time delay range from 0.05 seconds to 300 hours, this relay offers flexibility to suit a wide range of timing requirements.
1 CO (Changeover) Contact: Equipped with 1 changeover contact, it allows you to switch between different circuits or devices with ease.
Voltage Compatibility: This relay is compatible with a wide range of 24-240V AC/DC, making it adaptable to various voltage inputs.
Symmetrical Flashing Functionality: The symmetrical flashing function adds versatility to your timing control, providing an essential tool for various applications.
Technical Specifications:
Timing Range: 0.05s - 300h
Contact Configuration: 1 CO (Changeover) Contact
Voltage Compatibility: 24-240V AC/DC
Specifications
Main | |
Range of product | Harmony Timer Relays |
Product or component type | Dual function relay |
Discrete output type | Relay |
Device short name | RE22 |
Nominal output current | 08:00 ص |
Complementary | |
Contacts type and composition | 1 C/O timed contact, cadmium free |
Time delay type | Symmetrical flashing |
Time delay range | 0.05...1 s |
30...300 h | |
30...300 min | |
30...300 s | |
3...30 min | |
1...10 s | |
3...30 s | |
0.3...3 s | |
10...100 s | |
3...30 h | |
Control type | Rotary knob |
Diagnostic button | |
[Us] rated supply voltage | 24...240 V AC/DC 50/60 Hz |
Release input voltage | <= 2.4 V |
Voltage range | 0.85...1.1 Us |
Supply frequency | 50...60 Hz +/- 5 % |
Connections - terminals | Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end |
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end | |
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end | |
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end | |
Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
Housing material | Self-extinguishing |
Repeat accuracy | +/- 0.5 % conforming to IEC 61812-1 |
Temperature drift | +/- 0.05 %/°C |
Voltage drift | +/- 0.2 %/V |
Setting accuracy of time delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
Control signal pulse width | 100 ms with load in parallel |
30 ms | |
Insulation resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
Recovery time | 120 ms on de-energisation |
Immunity to microbreaks | 10 ms |
Power consumption in VA | 3 VA at 240 V AC |
Power consumption in W | 1.5 W at 240 V DC |
Switching capacity in VA | 2000 VA |
Minimum switching current | 10 mA at 5 V DC |
Maximum switching current | 08:00 ص |
Maximum switching voltage | 250 V AC |
Electrical durability | 100000 cycles, 8 A at 250 V, AC-1 |
100000 cycles, 2 A at 24 V, DC-1 | |
Mechanical durability | 10000000 cycles |
Rated impulse withstand voltage | 5 kV for 1.2…50 µs conforming to IEC 60664-1 |
Power on delay | 100 ms |
Creepage distance | 4 kV/3 conforming to IEC 60664-1 |
Overvoltage category | III conforming to IEC 60664-1 |
Safety reliability data | B10d = 280000 |
MTTFd = 308.2 years | |
Mounting position | Any position |
Mounting support | 35 mm DIN rail conforming to IEC 60715 |
Status LED | LED backlight green (steady) for dial pointer indication |
LED yellow (steady) for output relay energised | |
LED yellow (fast flashing) for timing in progress and output relay de-energised | |
LED yellow (slow flashing) for timing in progress and output relay energised | |
Width | 22.5 mm |
Net weight | 0.1 kg |
Environment | |
Dielectric strength | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1 |
standards | UL 508 |
IEC 61812-1 | |
Directives | 2004/108/EC - electromagnetic compatibility |
2006/95/EC - low voltage directive | |
product certifications | GL |
EAC | |
UL | |
CCC | |
CSA | |
CE | |
RCM | |
Ambient air temperature for operation | -20…60 °C |
Ambient air temperature for storage | -40…70 °C |
IP degree of protection | IP40 housing: conforming to IEC 60529 |
IP50 front face: conforming to IEC 60529 | |
IP20 terminals: conforming to IEC 60529 | |
Pollution degree | 3 conforming to IEC 60664-1 |
Vibration resistance | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 15 gn not operating for 11 ms conforming to IEC 60068-2-27 |
5 gn in operation for 11 ms conforming to IEC 60068-2-27 | |
Relative humidity | 95 % at 25…55 °C |
Electromagnetic compatibility | Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 |
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 | |
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 | |
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 | |
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 | |
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 | |
Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 | |
Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 | |
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 | |
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 |