The SR2D201FU is a compact smart relay from the Zelio Logic series. This model features 20 I/O (Input/Output) points and operates with a voltage range of 100 to 240V AC. It does not include a clock or display. Compact smart relays like the SR2D201FU offer versatile control and automation solutions for various industrial applications.
Key Features:
Compact Design: The compact and space-saving design of this smart relay makes it suitable for installations with limited space.
20 I/O Points: With 20 I/O points, this relay allows flexible connectivity and control of various devices and sensors.
Wide Voltage Range: It is compatible with a voltage range of 100 to 240V AC, making it adaptable to different industrial power sources.
The SR2D201FU is a reliable and adaptable solution for industrial automation and control applications where a clock and display are not required.
Specifications
Main | |
Range of product | Zelio Logic |
Product or component type | Compact smart relay |
Complementary | |
Local display | Without |
Number or control scheme lines | 240 with ladder programming |
Cycle time | 6…90 ms |
Backup time | 10 years at 25 °C |
Clock drift | 12 min/year at 0…55 °C |
6 s/month at 25 °C | |
Checks | Program memory on each power up |
[Us] rated supply voltage | 100...240 V AC |
Supply voltage limits | 85…264 V |
Supply frequency | 50/60 Hz |
Maximum supply current | 100 mA at 100 V (without extension) |
50 mA at 240 V (without extension) | |
Power consumption in VA | 11 VA without extension |
Isolation voltage | 1780 V |
Protection type | Against inversion of terminals (control instructions not executed) |
Discrete input number | 12 |
Discrete input voltage | 100...240 V AC |
Discrete input current | 0.6 mA |
Discrete input frequency | 57...63 Hz |
47...53 Hz | |
Voltage state 1 guaranteed | >= 79 V for discrete input |
Voltage state 0 guaranteed | <= 40 V for discrete input |
Current state 1 guaranteed | >= 0.17 mA (discrete input) |
Current state 0 guaranteed | <= 0.5 mA (discrete input) |
analogue input number | 0 |
Input impedance | 350 kOhm for discrete input |
Number of outputs | 8 relay |
Output voltage limits | 5...30 V DC (relay output) |
24...250 V AC | |
Contacts type and composition | NO for relay output |
Output thermal current | 8 A for all 8 outputs for relay output |
Electrical durability | AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1 |
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1 | |
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1 | |
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1 | |
Switching capacity in mA | >= 10 mA at 12 V (relay output) |
Operating rate in Hz | 0.1 Hz (at Ie) for relay output |
10 Hz (no load) for relay output | |
Mechanical durability | 10000000 cycles for relay output |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 |
clock | Without |
Response time | 50 ms with ladder programming (from state 0 to state 1) for discrete input |
50 ms with ladder programming (from state 1 to state 0) for discrete input | |
50...255 ms with FBD programming (from state 0 to state 1) for discrete input | |
50...255 ms with FBD programming (from state 1 to state 0) for discrete input | |
10 ms (from state 0 to state 1) for relay output | |
5 ms (from state 1 to state 0) for relay output | |
Connections - terminals | Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid |
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid | |
Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end | |
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid | |
Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end | |
tightening torque | 0.5 N.m |
Overvoltage category | III conforming to EN/IEC 60664-1 |
Net weight | 0.35 kg |
Environment | |
Immunity to microbreaks | 10 ms |
product certifications | UL |
GOST | |
GL | |
CSA | |
C-Tick | |
standards | EN/IEC 61000-4-2 level 3 |
EN/IEC 61000-4-12 | |
EN/IEC 61000-4-11 | |
EN/IEC 60068-2-6 Fc | |
EN/IEC 61000-4-5 | |
EN/IEC 60068-2-27 Ea | |
EN/IEC 61000-4-6 level 3 | |
EN/IEC 61000-4-3 | |
EN/IEC 61000-4-4 level 3 | |
IP degree of protection | IP20 (terminal block) conforming to IEC 60529 |
IP40 (front panel) conforming to IEC 60529 | |
Environmental characteristic | EMC directive conforming to EN/IEC 61000-6-2 |
EMC directive conforming to EN/IEC 61000-6-3 | |
EMC directive conforming to EN/IEC 61000-6-4 | |
EMC directive conforming to EN/IEC 61131-2 zone B | |
Low voltage directive conforming to EN/IEC 61131-2 | |
Disturbance radiated/conducted | Class B conforming to EN 55022-11 group 1 |
Pollution degree | 2 conforming to EN/IEC 61131-2 |
Ambient air temperature for operation | -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 |
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2 | |
Ambient air temperature for storage | -40…70 °C |
Operating altitude | 2000 m |
Maximum altitude transport | 3048 m |
Relative humidity | 95 % without condensation or dripping water |