Description

The Schneider Electric C25N32D160 is a high-quality circuit breaker designed for robust performance and protection in a range of electrical applications. With a current rating of 160A and three poles, it's built to ensure the safe and reliable operation of your electrical circuits.

 

Key Features:

High Performance: This circuit breaker is part of the Compact NSX range, known for its high performance and reliable protection. It's designed to handle heavy electrical loads and provide exceptional performance in demanding environments.

Robust Construction: Schneider Electric products are known for their durability, and the C25N32D160 is no exception. It's built to last and withstand the test of time, ensuring that your electrical systems stay protected.

Micrologic 2.2 Trip Unit: The Micrologic trip unit ensures precise and adjustable protection settings, enhancing the safety of your electrical installation.

Multiple Applications: This circuit breaker is suitable for a wide range of applications, making it a versatile choice for your electrical protection needs.

 

Whether you need reliable circuit protection in an industrial setting or for commercial applications, the Schneider Electric C25N32D160 is a dependable choice.

 

Specifications  

Main

 
Range ComPacT new generation
Product name ComPacT NSX new generation
device short name NSX250N
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3D
[In] rated current 160 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
  10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
  15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance level N 50 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
control type Toggle
Circuit breaker mounting mode Fixed
Complementary  
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
  10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
  10000 cycles at 440 V In
  10000 cycles at 690 V In/2
  5000 cycles at 690 V In
Power dissipation per pole 7.17 W
mounting support Backplate
Mounting position Horizontal and vertical
  Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time)
  So : for short time short-circuit protection with fixed delay
  I : for instantaneous short-circuit protection
Trip unit rating 160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 63...160 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir
  16 s at 6 x Ir
  11 s at 7.2 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 2400 A
earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate
  LED 105 % Ir (red) for overload
  LED 90 % Ir (orange) for overload
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.4 kg
Environment  
standards EN/IEC 60947

 

 

 

 

Specifications

More Information
Weight 2.400000
Brand Schneider Electric
Model C25N32D160
Device Application Distribution
Depth [cm] 8.6
Width [cm] 10.5
Height [cm] 16.1
Range NSX
Family PPCCB
Type Circuit Breaker
Poles 3P
[In] Rated Current 160 A at 40 °C