Compact NSX160F Circuit Breaker, 36kA at 415VAC, TMD Trip Unit, 100A, 4 Poles

In stock
SKU
C16F6TM100
Special Price EGP 17,686 Regular Price EGP 27,634

Description

Explore the Schneider Electric Compact NSX160F Circuit Breaker, a reliable and efficient solution for circuit protection. Designed to ensure the safety of your electrical systems, this circuit breaker offers dependable protection against overloads and short circuits, making it an essential component for various applications.

 

Key Features:

High Breaking Capacity: With a 36kA breaking capacity at 415VAC, this circuit breaker is well-equipped to handle high fault currents, enhancing the safety of your electrical circuits.

100A Rating: The 100A rating makes it suitable for a wide range of applications, whether it's for residential, commercial, or industrial use.

TMD Trip Unit: Equipped with a TMD trip unit, it offers precise and adjustable protection settings, allowing you to customize the breaker's response according to your specific needs.

4-Pole Configuration: The 4-pole design ensures versatility and additional options for electrical circuit configurations.

Reliable Circuit Protection: This circuit breaker ensures the reliability and safety of your electrical systems.

Technical Specifications:

Breaking Capacity: 36kA at 415VAC

Current Rating: 100A

Poles: 4

Trip Unit: TMD

 

Specifications  

Main

 
Range ComPacT new generation
Product name ComPacT NSX new generation
device short name NSX160F
Product or component type Circuit breaker
Device application Distribution
Poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
  8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA at 480 V AC 50/60 Hz conforming to UL 508
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
control type Toggle
Circuit breaker mounting mode Fixed
Complementary  
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
  30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
  22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
  8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 40000 cycles
Electrical durability 40000 cycles at 440 V In/2
  20000 cycles at 440 V In
  15000 cycles at 690 V In/2
  7500 cycles at 690 V In
Power dissipation per pole 7.7 W
mounting support Backplate
Mounting position Horizontal and vertical
  Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
  I : for short-circuit protection (magnetic)
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
  15 s at 6 x Ir
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 800 A
earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.6 kg
Environment  
standards EN/IEC 60947
product certifications CCC
  EAC
  Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating
  2000 m...5000 m with derating

 

 

Specifications

More Information
Weight 2.600000
Brand Schneider Electric
Model C16F6TM100
Device Application Distribution
Depth [cm] 8.6
Width [cm] 14
Height [cm] 16.1
Range NSX
Family PPCCB
Type Circuit Breaker
Poles 4P
[In] Rated Current 100 A at 40 °C

Reviews

You're reviewing:

Compact NSX160F Circuit Breaker, 36kA at 415VAC, TMD Trip Unit, 100A, 4 Poles