Introducing the Schneider Electric Compact NSX100H Circuit Breaker, a reliable and high-performance solution for circuit protection. Engineered to ensure the safety and efficiency of your electrical systems, this circuit breaker offers robust protection capabilities, making it suitable for a variety of applications.
Key Features:
High Breaking Capacity: With an impressive 70kA breaking capacity at 415VAC, this circuit breaker can handle high fault currents, enhancing the safety of your electrical circuits.
3 Poles: The 3-pole configuration adds versatility to your electrical system, making it suitable for various applications and installations.
TMD Trip Unit: Equipped with the advanced TMD trip unit, this circuit breaker offers intelligent protection with enhanced features for precise fault detection and response.
25A Rating: The 25A rating allows this circuit breaker to handle moderate electrical loads while providing reliable protection.
3D Compatibility: The 3D designation signifies its compatibility with a range of tripping units, ensuring flexible protection options.
Technical Specifications:
Breaking Capacity: 70kA at 415VAC
Poles: 3
Trip Unit Type: TMD
Current Rating: 25A
Tripping Units Compatibility: 3D
Specifications | |
Main |
|
Range | ComPacT new generation |
Product name | ComPacT NSX new generation |
device short name | NSX100H |
Product or component type | Circuit breaker |
Device application | Distribution |
Poles description | 3P |
Protected poles description | 3D |
[In] rated current | 25 A at 40 °C |
[Ue] rated operational voltage | 690 V AC 50/60 Hz |
Network type | AC |
Network frequency | 50/60 Hz |
Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
utilisation category | Category A |
[Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 | |
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | H 70 kA 415 V AC |
Trip unit name | TM-D |
Trip unit technology | Thermal-magnetic |
Trip unit protection functions | LI |
control type | Toggle |
Circuit breaker mounting mode | Fixed |
Complementary | |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
[Ics] rated service short-circuit breaking capacity | 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 | |
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Mechanical durability | 50000 cycles |
Electrical durability | 50000 cycles at 440 V In/2 |
30000 cycles at 440 V In | |
20000 cycles at 690 V In/2 | |
10000 cycles at 690 V In | |
Power dissipation per pole | 4.01 W |
mounting support | Backplate |
Mounting position | Horizontal and vertical |
Flat on the back | |
Upside connection | Front |
downside connection | Front |
Connection pitch | 35 mm |
Protection type | L : for overload protection (thermal) |
I : for short-circuit protection (magnetic) | |
Trip unit rating | 25 A at 40 °C |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
[Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
Long-time protection delay adjustment type tr | Fixed |
[tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In |
15 s at 6 x Ir | |
Instantaneous protection pick-up adjustment type Ii | Fixed |
[Ii] instantaneous protection pick-up adjustment range | 300 A |
earth-leakage protection | Without |
Number of slots for electrical auxiliaries | 5 slot(s) |
Width (W) | 105 mm |
Height (H) | 161 mm |
Depth (D) | 86 mm |
Net weight | 2.05 kg |
Environment | |
standards | EN/IEC 60947 |
product certifications | CCC |
EAC | |
Marine | |
Overvoltage category | Class II |
Electrical shock protection class | Class II |
Pollution degree | 3 conforming to IEC 60664-1 |
IP degree of protection | IP40 conforming to IEC 60529 |
IK degree of protection | IK07 conforming to IEC 62262 |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -50…85 °C |
Relative humidity | 0…95 % |
Operating altitude | 0...2000 m without derating |
2000 m...5000 m with derating |