Compact NSX100F Circuit Breaker, 36kA at 415VAC, TMD Trip Unit, 25A, 3 Poles, 3D

In stock
SKU
C10F3TM025
Special Price EGP 10,925 Regular Price EGP 16,553

Description

Introducing the Schneider Electric Compact NSX100F Circuit Breaker, a reliable and high-performance solution for circuit protection. Engineered to ensure the safety and efficiency of your electrical systems, this circuit breaker offers robust protection capabilities, making it suitable for a variety of applications.

 

Key Features:

High Breaking Capacity: With an impressive 36kA breaking capacity at 415VAC, this circuit breaker can handle high fault currents, enhancing the safety of your electrical circuits.

3 Poles: The 3-pole configuration adds versatility to your electrical system, making it suitable for various applications and installations.

TMD Trip Unit: Equipped with the advanced TMD trip unit, this circuit breaker offers intelligent protection with enhanced features for precise fault detection and response.

25A Rating: The 25A rating allows this circuit breaker to handle moderate electrical loads while providing reliable protection.

3D Compatibility: The 3D designation signifies its compatibility with a range of tripping units, ensuring flexible protection options.

Technical Specifications:

Breaking Capacity: 36kA at 415VAC

Poles: 3

Trip Unit Type: TMD

Current Rating: 25A

Tripping Units Compatibility: 3D

 

Specifications  

Main

 
Range ComPacT new generation
Product name ComPacT NSX new generation
device short name NSX100F
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3D
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
  8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
control type Toggle
Circuit breaker mounting mode Fixed
Complementary  
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
  12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
  11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
  4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
  30000 cycles at 440 V In
  20000 cycles at 690 V In/2
  10000 cycles at 690 V In
Power dissipation per pole 4.01 W
mounting support Backplate
Mounting position Horizontal and vertical
  Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
  I : for short-circuit protection (magnetic)
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
  15 s at 6 x Ir
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 300 A
earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.05 kg
Environment  
standards EN/IEC 60947
product certifications CCC
  EAC
  Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating
  2000 m...5000 m with derating

 

 

 

 

Specifications

More Information
Weight 2.050000
Brand Schneider Electric
Model C10F3TM025
Device Application Distribution
Depth [cm] 8.6
Width [cm] 10.5
Height [cm] 16.1
Range NSX
Family PPCCB
Type Circuit Breaker
Poles 3P
[In] Rated Current 25 A at 40 °C