Compact NSX100F Circuit Breaker, 36kA at 415VAC, Micrologic 2.2 Trip Unit, 100A, 4 Poles, 4D

Out of stock
SKU
C10F42D100
Special Price EGP 24,709 Regular Price EGP 37,438

Description

Introducing the Schneider Electric Compact NSX100F Circuit Breaker, a reliable and high-performance solution for circuit protection. Engineered to ensure the safety and efficiency of your electrical systems, this circuit breaker offers robust protection capabilities, making it suitable for a variety of applications.

 

Key Features:

High Breaking Capacity: With an impressive 36kA breaking capacity at 415VAC, this circuit breaker can handle high fault currents, enhancing the safety of your electrical circuits.

4 Poles: The 4-pole configuration adds versatility to your electrical system, making it suitable for various applications and installations.

Micrologic 2.2 Trip Unit: Equipped with the advanced Micrologic 2.2 trip unit, this circuit breaker offers intelligent protection with enhanced features for precise fault detection and response.

100A Rating: The 100A rating allows this circuit breaker to handle moderate to heavy electrical loads while providing reliable protection.

4D Compatibility: The 4D designation signifies its compatibility with a range of tripping units, ensuring flexible protection options.

Technical Specifications:

Breaking Capacity: 36kA at 415VAC

Poles: 4

Trip Unit Type: Micrologic 2.2

Current Rating: 100A

Tripping Units Compatibility: 4D

Specifications  

Main

 
Range ComPacT new generation
Product name ComPacT NSX new generation
device short name NSX100F
Product or component type Circuit breaker
Device application Distribution
Poles description 4P
Protected poles description 4D
  3D + N/2
  3D
Neutral position Left
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
  8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
control type Toggle
Circuit breaker mounting mode Fixed
Complementary  
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
  12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
  11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
  4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
  30000 cycles at 440 V In
  20000 cycles at 690 V In/2
  10000 cycles at 690 V In
Power dissipation per pole 4.7 W
mounting support Backplate
Mounting position Horizontal and vertical
  Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time)
  So : for short time short-circuit protection with fixed delay
  I : for instantaneous short-circuit protection
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir
  16 s at 6 x Ir
  11 s at 7.2 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2)
  1 x Ir (4D)
  No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate
  LED 105 % Ir (red) for overload
  LED 90 % Ir (orange) for overload
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm

 

 

Specifications

More Information
Weight 2.400000
Brand Schneider Electric
Model C10F42D100
Device Application Distribution
Depth [cm] 8.6
Width [cm] 14
Height [cm] 16.1
Range NSX
Family PPCCB
Type Circuit Breaker
Poles 4P
[In] Rated Current 100 A at 40 °C

Reviews

You're reviewing:

Compact NSX100F Circuit Breaker, 36kA at 415VAC, Micrologic 2.2 Trip Unit, 100A, 4 Poles, 4D