For independent control of up to 8 blind/roller shutter drives or for switching up to 16 loads via make contacts. The function of the blind or switching channels is freely configurable. All blind/switch outputs can be operated manually using push-buttons. The bus is connected using a bus connecting terminal. A data rail is not necessary. Channel status display via LEDs. A green LED indicates readiness for operation. With integrated bus coupler. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Blind functions: Blind type. Running time. Idle time. Step interval. Weather alarm. 8-bit positioning for height and slats. Scenes. Status and feedback function. Switch actuator functions: Operation as break contact/make contact. Programmable behaviour for download. Delay functions for each channel. Staircase lighting function with/without manual OFF function. Cut-out warning for staircase lighting function. Scenes. Central function. Disable function. Logic operation or priority control. Status feedback function for each channel. Nominal voltage: AC 100-240 V ±10%. Operating voltage: min. AC 90 V - max. AC 265 V. Mains frequency: 50-60 Hz ±10%. For each blind output: Nominal current: 10 A, inductive load cos Phi 0.6. Motor load: AC 100 V, max. 434 W. AC 230 V, max. 1000 W. AC 240 V, max. 1043 W. For each switch output: Nominal current: 10 A, ohmic load cos Phi 1. 10 A, inductive load cos Phi 0.6. Nominal load. Incandescent lamps: AC 100 V, max. 869 W. AC 230 V, max. 2000 W. AC 240 V, max. 2086 W. Halogen lamps: AC 100 V, max. 739 W. AC 230 V, max. 1700 W. AC 240 V, max. 1773 W. Fluorescent lamps: AC 100 V, max. 434 VA.AC 230 V, max. 1000 VA. AC 240 V, max. 1043 VA. parallel-compensated. Capacitive load: AC 230 V, 10 A, max. 105 µF. External auxiliary voltage: Nominal voltage: AC 110-240 V ±10%. Device width: 8 modules, approx. 144 mm. Contents: With bus connecting terminal and cable cover.
Specifications:
Main |
|
Range of product |
KNX |
product or component type |
Blind switch actuator |
Operating mode |
KNX bus system |
Manual |
|
Bus type |
KNX |
Complementary |
|
total number of 18 mm modules |
8 |
mounting support |
DIN rail |
[Ue] rated operational voltage |
100...240 V AC 50...60 Hz |
[In] rated current |
10:00 AM |
number of outputs |
8 |
Load type |
Motor: 434 W, 100 V AC |
Motor: 1000 W, 230 V AC |
|
Motor: 1043 W, 240 V AC |
|
Incandescent lamps: <= 869 W, 100 V AC |
|
Incandescent lamps: <= 2000 W, 230 V AC |
|
Incandescent lamps: <= 2086 W, 240 V AC |
|
Halogen lamps: <= 739 W, 100 V AC |
|
Halogen lamps: <= 1700 W, 230 V AC |
|
Halogen lamps: <= 1773 W, 240 V AC |
|
Parallel compensated fluorescent lamp: <= 434 VA, 100 V AC |
|
Parallel compensated fluorescent lamp: <= 1000 VA, 230 V AC |
|
Parallel compensated fluorescent lamp: <= 1043 VA, 240 V AC |
|
Capacitive: , 10 A, 105 µF, 100...240 V AC |
|
local signalling |
LED |
Environment |
|
IP degree of protection |
IP20 |