High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions.
Specifications:
Main |
|
Run time for load |
2min 52s |
Main Input Voltage |
230 V |
Product or component type |
Uninterruptible power supply (UPS) |
Other Input Voltage |
220 V |
240 V |
|
Main Output Voltage |
230 V |
Other Output Voltage |
220 V |
240 V |
|
Rated power in W |
10000 W |
Rated power in VA |
10000 VA |
Output connector type |
Hard wire 3-wire (1P + N + E) 1 |
Number of rack unit |
4U |
Provided equipment |
1 USB cable |
1 RS-232 configuration cable |
|
2 rack mounting brackets |
|
1 external battery pack |
|
1 battery cable |
|
user manual |
|
Range of product |
Easy UPS On-Line |
Batteries & Runtime |
|
Battery type |
Lead-acid battery |
Battery voltage |
192 V |
Number of battery filled slots |
0 |
Number of battery free slots |
0 |
Battery recharge time |
5 h |
Battery life |
3…5 year(s) |
Battery charger power |
235 W rated |
General |
|
Number of power module filled slots |
0 |
Number of power module free slots |
0 |
Redundant |
No |
Physical |
|
Colour |
Black (RAL 7010) |
Height |
17.3 cm |
Width |
43.8 cm |
Depth |
71.0 cm |
Net weight |
68 kg |
mounting location |
Front |
Mounting preference |
Lower |
mounting mode |
Rack-mounted with kit |
USB compatible |
Yes |
Mounting position |
Horizontal |
Input |
|
Input voltage limits |
110...300 V 60 % load |
176...300 V full load |
|
Number of input connectors |
1 hard wire 3-wire (1P + N + E) |
Network frequency |
40...70 Hz auto sensing |
Output |
|
Maximum configurable power in VA |
10000 VA |
Maximum configurable power in W |
10000 W |
Output frequency |
50/60 Hz +/- 3 Hz sync to mains |
Harmonic distortion |
1% |
UPS type |
Double conversion online |
Wave type |
Sine wave |
Efficiency |
94 % (full load) |
Bypass type |
Internal bypass (automatic and manual) |
Crest factor |
3:1 |
Conformance |
|
product certifications |
CE |
UKCA |
|
EAC |
|
TISI |
|
Standards |
EN/IEC 62040-1:2019/A11:2021 |
EN/IEC 62040-2:2006/AC:2006 |
|
EN/IEC 62040-2:2018 |
|
Environmental |
|
Ambient air temperature for operation |
0…40 °C |
Relative humidity |
0…95 % non-condensing |
Operating altitude |
0...3000 m |
Ambient air temperature for storage |
-15…60 °C |
Storage Relative Humidity |
0…95 % non-condensing |
Storage altitude |
0…15000 m |
acoustic level |
58 dB |
Heat dissipation |
2128 Btu/h |
IP degree of protection |
IP20 |
Communications & Management |
|
Alarm |
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Emergency power off |
Yes |
Free slots |
1 |
Control panel |
Multifunction LCD status and control console |
Surge Protection and Filtering |
|
Surge energy rate |
600 J |